No. of sale: 260423LA
Starting dateManufacturerTECAN Model6 positions ObservationsHPV sample extraction equipment for 48 samples.
6 positions
48 samples
ManufacturerTECAN Model6 positions ObservationsHPV sample extraction equipment for 48 samples.
6 positions
48 samples
Start price 15.000 €
ManufacturerTECAN Model9 positions ObservationsHPV sample extraction equipment .
9 positions
96 samples
ManufacturerTECAN Model9 positions ObservationsHPV sample extraction equipment .
9 positions
96 samples
Start price 20.000 €
ManufacturerTECAN Model9 positions ObservationsHPV sample extraction equipment .
9 positions
96 samples
ManufacturerTECAN Model9 positions ObservationsHPV sample extraction equipment .
9 positions
96 samples
Start price 20.000 €
ManufacturerThermo Scientific ModelKing Fisher Flex ObservationsEquipment for automated extraction of 24 or 96 samples per stroke. It offers consistent extraction and purification of DNA, RNA, proteins and cells of medium to high yield. High performance purification: 24-96 samples per stroke, Plate format: Wide volume range of 20 μl-5 ml. Processing volume range: PCR plate (20-100 μl), with skirt (or PCR plate with similar skirt): 20-200 μl: 96-well plate. 50-1000 μl: Plate of 96 deep wells. 200-5000 μl: 24-well deep plate. Software included, BindIt, Customizable protocols, Yes (with BindIt software), Heating and cooling: From 5°C above ambient temperature to 115°C, Barcode reader, User-selectable magnetic heads: 4.
ManufacturerThermo Scientific ModelKing Fisher Flex ObservationsEquipment for automated extraction of 24 or 96 samples per stroke. It offers consistent extraction and purification of DNA, RNA, proteins and cells of medium to high yield. High performance purification: 24-96 samples per stroke, Plate format: Wide volume range of 20 μl-5 ml. Processing volume range: PCR plate (20-100 μl), with skirt (or PCR plate with similar skirt): 20-200 μl: 96-well plate. 50-1000 μl: Plate of 96 deep wells. 200-5000 μl: 24-well deep plate. Software included, BindIt, Customizable protocols, Yes (with BindIt software), Heating and cooling: From 5°C above ambient temperature to 115°C, Barcode reader, User-selectable magnetic heads: 4.
CLOSED
ManufacturerScienion ModelSciflexarrayer S11 Year2014 No. Series2030014 ObservationsFully automated non-contact dispensing system for ultra-low volumes. Dispense Volume: 30 - 800 pL/drop, No. of Dispense Capillaries From 1 to 8 PDC channels, Distance Dispense Capillaries: 4.5 or 9 mm increments. Target Holder: 380 x 380 mm Capacity Up to 11 MTPs or 70 standard glass slides. Axis system X-Y linear magnetic & Z spindle drives. Resolution (step size) 1 µm. Precision < 3 µm. Accuracy < 5 µm. Options Spot-on-the-fly, 3D drop camera, vacuum target holder, online target alignment, online array QC software. Dimensions (L,W,H) with enclosure 1300 x 850 x 1200 mm. Weight 420 kg
ManufacturerScienion ModelSciflexarrayer S11 Year2014 No. Series2030014 ObservationsFully automated non-contact dispensing system for ultra-low volumes. Dispense Volume: 30 - 800 pL/drop, No. of Dispense Capillaries From 1 to 8 PDC channels, Distance Dispense Capillaries: 4.5 or 9 mm increments. Target Holder: 380 x 380 mm Capacity Up to 11 MTPs or 70 standard glass slides. Axis system X-Y linear magnetic & Z spindle drives. Resolution (step size) 1 µm. Precision < 3 µm. Accuracy < 5 µm. Options Spot-on-the-fly, 3D drop camera, vacuum target holder, online target alignment, online array QC software. Dimensions (L,W,H) with enclosure 1300 x 850 x 1200 mm. Weight 420 kg
Start price 7.500 €
ManufacturerScienion ModelSciflexarrayer S12 Year2015 No. Series1020015 ObservationsFully automated non-contact dispensing system for ultra-low volumes. Dispense Volume: 30 - 800 pL/drop, No. of Dispense Capillaries From 1 to 8 PDC channels, Distance Dispense Capillaries: 4.5 or 9 mm increments. Target Holder: 380 x 380 mm Capacity Up to 12 MTPs or 70 standard glass slides. Axis system X-Y linear magnetic & Z spindle drives. Resolution (step size) 1 µm. Precision < 3 µm. Accuracy < 5 µm. Options Spot-on-the-fly, 3D drop camera, vacuum target holder, online target alignment, online array QC software. Dimensions (L,W,H) with enclosure 1300 x 850 x 1200 mm. Weight 420 kg
ManufacturerScienion ModelSciflexarrayer S12 Year2015 No. Series1020015 ObservationsFully automated non-contact dispensing system for ultra-low volumes. Dispense Volume: 30 - 800 pL/drop, No. of Dispense Capillaries From 1 to 8 PDC channels, Distance Dispense Capillaries: 4.5 or 9 mm increments. Target Holder: 380 x 380 mm Capacity Up to 12 MTPs or 70 standard glass slides. Axis system X-Y linear magnetic & Z spindle drives. Resolution (step size) 1 µm. Precision < 3 µm. Accuracy < 5 µm. Options Spot-on-the-fly, 3D drop camera, vacuum target holder, online target alignment, online array QC software. Dimensions (L,W,H) with enclosure 1300 x 850 x 1200 mm. Weight 420 kg
Start price 7.500 €
ManufacturerEppendorf ModelBioPhotometer plus 6132 No. Series6132 01465 ObservationsTechnical data: Photometer: Measuring principle: Absorption single beam photometer with reference beam and several fixed wavelenghts. Light source: Xenon flash light. Monochromator: Holographic concave grating. Beam receiver: Silicon photo diodes. Wavelengths: 230, 260, 280, 340, 405, 490, 550, 595, 650 nm. Wavelength selection: Dependent on method, controlled by program. Spectral bandwidth 5 nm at 230 to 340 nm, 7 nm at 405 to 650 nm. Photometric measuring range Quartz glass cuvette: • A = 0 to 3, except: • A = 0 to 2 at 340 nm, • Only for dye methods: A = 0 to 2 at 550/650 nm, UVette (Eppendorf): • A = 0 to 2.5 at 230 nm, • A = 0 to 2.6 at 260 nm, • A = 0 to 2.8 at 280 nm, • Other values see quartz glass cuvette, Reading accuracy ΔA = 0.001, Random photometric error ≤ 0.002 at A = 0, ≤ 0.005 at A = 1. Systematic photometric error ± 1% at A = 1. Stray light component < 0.05 %. Power supply: Power supply 100 to 240 V ± 10 % / 50 to 60 Hz ± 5 %. Overvoltage category IEC 61010-1 category II. Degree of contamination: IEC 61010-1 category II. Power consumption approx. 20 W Weight / dimensions: Weight 3 kg. Dimensions Width: 200 mm, Depth: 320 mm, Height: 100 mm, Space required Width: 400 mm (or 650 mm including printer), Depth: 500 mm. Interfaces: Interface for printer and PC serial RS-232
ManufacturerEppendorf ModelBioPhotometer plus 6132 No. Series6132 01465 ObservationsTechnical data: Photometer: Measuring principle: Absorption single beam photometer with reference beam and several fixed wavelenghts. Light source: Xenon flash light. Monochromator: Holographic concave grating. Beam receiver: Silicon photo diodes. Wavelengths: 230, 260, 280, 340, 405, 490, 550, 595, 650 nm. Wavelength selection: Dependent on method, controlled by program. Spectral bandwidth 5 nm at 230 to 340 nm, 7 nm at 405 to 650 nm. Photometric measuring range Quartz glass cuvette: • A = 0 to 3, except: • A = 0 to 2 at 340 nm, • Only for dye methods: A = 0 to 2 at 550/650 nm, UVette (Eppendorf): • A = 0 to 2.5 at 230 nm, • A = 0 to 2.6 at 260 nm, • A = 0 to 2.8 at 280 nm, • Other values see quartz glass cuvette, Reading accuracy ΔA = 0.001, Random photometric error ≤ 0.002 at A = 0, ≤ 0.005 at A = 1. Systematic photometric error ± 1% at A = 1. Stray light component < 0.05 %. Power supply: Power supply 100 to 240 V ± 10 % / 50 to 60 Hz ± 5 %. Overvoltage category IEC 61010-1 category II. Degree of contamination: IEC 61010-1 category II. Power consumption approx. 20 W Weight / dimensions: Weight 3 kg. Dimensions Width: 200 mm, Depth: 320 mm, Height: 100 mm, Space required Width: 400 mm (or 650 mm including printer), Depth: 500 mm. Interfaces: Interface for printer and PC serial RS-232
CLOSED
ManufacturerThermoScientific ModelMultiskan No. Series357-703134 ObservationsMultiskan FC microplate photometer is a reliable instrument for a wide variety of routine and research applications. It reads 96- and 384-well plates and is equipped with agitation and incubation functions for critical temperature assays.ultiskan FC has a wavelength range of 340 to 850 nm, allowing a wide variety of applications: from kinetic studies of enzymes to Lowry assays. The instrument offers fast and accurate measurements that allow a complete reading of a 96-well plate in less than seven seconds. The instrument is also equipped with linear agitation as standard. A model with incubator allows incubation temperatures of up to 50 °C and the ability to read plates from 384 wells. SkanIt software enables optimal instrument utilization with visual workflow, effortless data analysis and export functions. A wide range of wavelengths from 340 to 850 nm.
ManufacturerThermoScientific ModelMultiskan No. Series357-703134 ObservationsMultiskan FC microplate photometer is a reliable instrument for a wide variety of routine and research applications. It reads 96- and 384-well plates and is equipped with agitation and incubation functions for critical temperature assays.ultiskan FC has a wavelength range of 340 to 850 nm, allowing a wide variety of applications: from kinetic studies of enzymes to Lowry assays. The instrument offers fast and accurate measurements that allow a complete reading of a 96-well plate in less than seven seconds. The instrument is also equipped with linear agitation as standard. A model with incubator allows incubation temperatures of up to 50 °C and the ability to read plates from 384 wells. SkanIt software enables optimal instrument utilization with visual workflow, effortless data analysis and export functions. A wide range of wavelengths from 340 to 850 nm.
CLOSED
ManufacturerEppendorf ModelMastercylcer Year2007 ObservationsThermocycler PCR optimization for research PCR applications such as food testing. Unit can control 9 other units in network. holds 1 PCR plate 8×12: 96 wells. unit can only be controlled with control panel. parámetro: 1-30 °C (gradient range), 30-99 °C (gradient temperature), 37-110 °C temp. range, 4-99 °C temp. range (control range). technique: PCR: suitable. Dimensions: An × P × Al: 27.5 cm × 43 cm × 33 cm. Peso: 11.5 kg.
ManufacturerEppendorf ModelMastercylcer Year2007 ObservationsThermocycler PCR optimization for research PCR applications such as food testing. Unit can control 9 other units in network. holds 1 PCR plate 8×12: 96 wells. unit can only be controlled with control panel. parámetro: 1-30 °C (gradient range), 30-99 °C (gradient temperature), 37-110 °C temp. range, 4-99 °C temp. range (control range). technique: PCR: suitable. Dimensions: An × P × Al: 27.5 cm × 43 cm × 33 cm. Peso: 11.5 kg.
CLOSED
ManufacturerApplied Biosystems ModelGene Amp 9700 No. Series805S7010401 ObservationsTemperature Accuracy ±0.25ºC (35ºC - 99.9ºC) Temperature Range 4.0ºC to 99.9ºC Sample Block 0.2 mL 96-well Max block ramp rate 2.0°/ Sec Max sample ramp rate 1.7°C/sec PCR Volume Range 10-100 µL Memory 120+ Methods* (depending on protocol length) Dimensions 16 x 12 x 12 in Weight 27 lbs Power 115V, 50/60Hz, 725W
ManufacturerApplied Biosystems ModelGene Amp 9700 No. Series805S7010401 ObservationsTemperature Accuracy ±0.25ºC (35ºC - 99.9ºC) Temperature Range 4.0ºC to 99.9ºC Sample Block 0.2 mL 96-well Max block ramp rate 2.0°/ Sec Max sample ramp rate 1.7°C/sec PCR Volume Range 10-100 µL Memory 120+ Methods* (depending on protocol length) Dimensions 16 x 12 x 12 in Weight 27 lbs Power 115V, 50/60Hz, 725W
CLOSED
ManufacturerEppendorf ModelMastercycler gradient No. Series533103702 ObservationsThermal cycler in a 96-well format. The Peltier element controls the temperature of the silver plated block with extremely fast heating and cooling rates. Freely programmable temperature gradients up to 20 °C allow optimization of not only annealing temperatures, but all temperature steps of PCR protocols, even for the most demanding applications. Optimum, constant heating and cooling rates are guaranteed thanks to the steady yslope technology, which means that the results of gradient experiments can be easily and precisely transferred to everyday applications. Application: For PCR experiments. Heated lid with integrated ESP technology (Electronic Sample Protection). Highest temperature speed due to silver block: up to 6 °C/s.
ManufacturerEppendorf ModelMastercycler gradient No. Series533103702 ObservationsThermal cycler in a 96-well format. The Peltier element controls the temperature of the silver plated block with extremely fast heating and cooling rates. Freely programmable temperature gradients up to 20 °C allow optimization of not only annealing temperatures, but all temperature steps of PCR protocols, even for the most demanding applications. Optimum, constant heating and cooling rates are guaranteed thanks to the steady yslope technology, which means that the results of gradient experiments can be easily and precisely transferred to everyday applications. Application: For PCR experiments. Heated lid with integrated ESP technology (Electronic Sample Protection). Highest temperature speed due to silver block: up to 6 °C/s.
CLOSED
ManufacturerEppendorf ModelMastercycler nexus SX1 No. Series6346GQ915682 ObservationsThermal cycler, allows you to select the consumables for PCR that best suit your test. The nexus PCR thermal cycler can accommodate 96-well PCR plates, 0.2 mL PCR tubes, 0.2 mL PCR tube strips and 0.5 mL PCR tubes. With a noise emission of less than 40 dB[a].
ManufacturerEppendorf ModelMastercycler nexus SX1 No. Series6346GQ915682 ObservationsThermal cycler, allows you to select the consumables for PCR that best suit your test. The nexus PCR thermal cycler can accommodate 96-well PCR plates, 0.2 mL PCR tubes, 0.2 mL PCR tube strips and 0.5 mL PCR tubes. With a noise emission of less than 40 dB[a].
CLOSED