No. of sale: 300621L
Starting dateManufacturerSALVIS LAB ModelLAB SC550 Year2018 ObservationsType No. SC 550 ; Code D24047 ; External Dim (W x H x D) 552 x 945 630mm ; Power Data V/ kW/ A 400/7.3/16 Weight357
ManufacturerSALVIS LAB ModelLAB SC550 Year2018 ObservationsType No. SC 550 ; Code D24047 ; External Dim (W x H x D) 552 x 945 630mm ; Power Data V/ kW/ A 400/7.3/16 Weight357
CLOSED
ManufacturerRICE LAKE- TROEMNER ModelUB0094 ObservationsPesa para calibración (25kg) Weight17
ManufacturerRICE LAKE- TROEMNER ModelUB0094 ObservationsPesa para calibración (25kg) Weight17
CLOSED
ManufacturerDATAMAX-O'NEIL ModelE-class Mark III Observationslabel printer - monochrome - direct thermal / thermal transmission - roll (11.2 cm) - 203 dpi - up to 127 mm / sec - parallel, USB 2.0, LAN, Equipment weight: 2.4 kg. Weight172
ManufacturerDATAMAX-O'NEIL ModelE-class Mark III Observationslabel printer - monochrome - direct thermal / thermal transmission - roll (11.2 cm) - 203 dpi - up to 127 mm / sec - parallel, USB 2.0, LAN, Equipment weight: 2.4 kg. Weight172
CLOSED
ManufacturerRICE LAKE- TROEMNER ModelUB0095 ObservationsCalibration weight (20kg) Weight16
ManufacturerRICE LAKE- TROEMNER ModelUB0095 ObservationsCalibration weight (20kg) Weight16
CLOSED
ManufacturerWALTER HERZOG GMBH ModelBA565 Weight32
ManufacturerWALTER HERZOG GMBH ModelBA565 Weight32
CLOSED
ManufacturerEDWARDS ModelRV5 No. Series66433737 ObservationsDisplacement: 50Hz. 5.8 m3h-1 / 3.4 ft 3min-1 60Hz. 7.0 m3h-1 / 4.1 ft3min-1 Speed (Pneurop 6602) 50Hz 5.1 m3h-1 / 3.0 ft 3min-1 60Hz 6.2 m3h-1 / 3.7 ft 3min-1 Ultimate pressure 2.0 x 10-3 mbar / 1.5 x 10-3 Torr Ultimate pressure GB I 3.0 x 10-2 mbar / 2.3 x 10-2 Torr Ultimate pressure GB II 1.0 x 10-1 mbar / 7.5 x 10-2 Torr Ultimate Pressure with Fomblin 2.0 x 10-2 mbar / 1.5 x 10-2 Torr Max inlet pressure for water vapour 50 mbar / 38 Torr Max water vapour pumping rate - GB I 60 gh-1 Max water vapour pumping rate - GB II 220 gh-1 Max allowed outlet pressure 0.2 bar gauge / 2.8 psig Max allowed inlet and gas ballast pressure 0.5 bar gauge / 7 psig Motor power 50/60Hz 450 / 550W 1500 / 1800rpm Weight (without oil) 25 kg / 55 lb Oil capacity min/max 0.42/0.7 litres Recommended oil Ultragrade 19 Inlet flange NW25 Operating temperature range 12 - 40 °C Electrical Supply 1 Ph, 100-120/200-230 VAC 50/60 Hz Weight41
ManufacturerEDWARDS ModelRV5 No. Series66433737 ObservationsDisplacement: 50Hz. 5.8 m3h-1 / 3.4 ft 3min-1 60Hz. 7.0 m3h-1 / 4.1 ft3min-1 Speed (Pneurop 6602) 50Hz 5.1 m3h-1 / 3.0 ft 3min-1 60Hz 6.2 m3h-1 / 3.7 ft 3min-1 Ultimate pressure 2.0 x 10-3 mbar / 1.5 x 10-3 Torr Ultimate pressure GB I 3.0 x 10-2 mbar / 2.3 x 10-2 Torr Ultimate pressure GB II 1.0 x 10-1 mbar / 7.5 x 10-2 Torr Ultimate Pressure with Fomblin 2.0 x 10-2 mbar / 1.5 x 10-2 Torr Max inlet pressure for water vapour 50 mbar / 38 Torr Max water vapour pumping rate - GB I 60 gh-1 Max water vapour pumping rate - GB II 220 gh-1 Max allowed outlet pressure 0.2 bar gauge / 2.8 psig Max allowed inlet and gas ballast pressure 0.5 bar gauge / 7 psig Motor power 50/60Hz 450 / 550W 1500 / 1800rpm Weight (without oil) 25 kg / 55 lb Oil capacity min/max 0.42/0.7 litres Recommended oil Ultragrade 19 Inlet flange NW25 Operating temperature range 12 - 40 °C Electrical Supply 1 Ph, 100-120/200-230 VAC 50/60 Hz Weight41
CLOSED
ManufacturerMKS BARATROM ModelTYPE 660 No. Series478995 ObservationsSingle-channel Digital Power Supply and Readout is a microprocessor-based power supply and readout module for use with capacitance manometers and mass flow meters requiring ±15 VDC and 250 mA maximum power, and any output signal in the range of 0 to 10 VDC. Weight51
ManufacturerMKS BARATROM ModelTYPE 660 No. Series478995 ObservationsSingle-channel Digital Power Supply and Readout is a microprocessor-based power supply and readout module for use with capacitance manometers and mass flow meters requiring ±15 VDC and 250 mA maximum power, and any output signal in the range of 0 to 10 VDC. Weight51
CLOSED
ManufacturerSARTORIUS ModelMD8 ObservationsFilter diameter 80 mm. Aluminum magazine to hold up to 10 filters. Air volume 2.5-8m³ / h. With transport case. Filter holder. Tube. 230 V. 50 Hz. 800 W. Digital display. Max. 62 dB (A). Weight62
ManufacturerSARTORIUS ModelMD8 ObservationsFilter diameter 80 mm. Aluminum magazine to hold up to 10 filters. Air volume 2.5-8m³ / h. With transport case. Filter holder. Tube. 230 V. 50 Hz. 800 W. Digital display. Max. 62 dB (A). Weight62
CLOSED
ManufacturerAGILENT ModelG3430-60151 ObservationsFP Analog and power PCA, for Agilent 7890 GC Weight118
ManufacturerAGILENT ModelG3430-60151 ObservationsFP Analog and power PCA, for Agilent 7890 GC Weight118
CLOSED
ManufacturerAGILENT ModelG1947A Year2014 ObservationsAgilent G1947A APCI Source (Atmospheric Pressure Chemical Ionization) Ion Source for use with LC/MSD system or with Bruker Esquire 3000. Weight119
ManufacturerAGILENT ModelG1947A Year2014 ObservationsAgilent G1947A APCI Source (Atmospheric Pressure Chemical Ionization) Ion Source for use with LC/MSD system or with Bruker Esquire 3000. Weight119
CLOSED