Gutinvest

Lots

Pharma and laboratory equipment

No. of sale: 300621L

Starting date
25/05/2021 14:00:00
Closing Date
30/06/2021 14:00:00
Viewing days
by appointment
Location
Gerona - Spain
Online auction of more than 350 lots, belonging to the pharmaceutical and biotechnology sector. We highlight tablet counters, encapsulators, packaging machines, cartoning machines, autoclaves, gas chromatographs, metal detectors, laminar flow cabinets, pipettes ...
Sales commission
18% buyers premium
Payment methods

Manufacturer
STERIS
Model
VHP100P-VHP100R

Weight
286

CLOSED

Manufacturer
STERIS
Model
VHP100P-VHP100R

Weight
286

CLOSED

Sold
93  -  Desiccant biodecontamination and regeneration system
500 €

Manufacturer
SEJONG

Weight
293

CLOSED

Manufacturer
SEJONG

Weight
293

CLOSED

Sold
94  -  Tablet cleaner
500 €

Manufacturer
LOCK INSPECT. SYSTEM
Model
MET 30+
Observations
The MET 30+ detector uses the latest developments in digital signal processingensuring complete product integrity. The detector is able to store up to 100 sets ofautomatic product set up values in memory.The MET 30+ detector is capable of detecting and rejecting ferrous, non-ferrous andnon-magnetic stainless steel.

Weight
301

CLOSED

Manufacturer
LOCK INSPECT. SYSTEM
Model
MET 30+
Observations
The MET 30+ detector uses the latest developments in digital signal processingensuring complete product integrity. The detector is able to store up to 100 sets ofautomatic product set up values in memory.The MET 30+ detector is capable of detecting and rejecting ferrous, non-ferrous andnon-magnetic stainless steel.

Weight
301

CLOSED

Sold
95  -  Metal detector
500 €

Manufacturer
IDI PHARMA
Model
DC
Year
2011

Weight
309

CLOSED

Manufacturer
IDI PHARMA
Model
DC
Year
2011

Weight
309

CLOSED

Sold
96  -  Tablet cleaner
500 €

Manufacturer
SOCO SYSTEM
Model
F-100.5
Observations
Medidas de caja: Max. L x W x H: Infinito x 520 x 505mm. Min. L x W x H 160 x 90 x 90/130mm. Capacidad Max.: 30/ min. Equipamiento elétrico 3 x 230/400 V, 50-60 Hz o 3 x 415/460 V, 50-60 Hz. Consumo 0,3 kW. Diametro de bobina máx. 370 mm.

Weight
345

CLOSED

Manufacturer
SOCO SYSTEM
Model
F-100.5
Observations
Medidas de caja: Max. L x W x H: Infinito x 520 x 505mm. Min. L x W x H 160 x 90 x 90/130mm. Capacidad Max.: 30/ min. Equipamiento elétrico 3 x 230/400 V, 50-60 Hz o 3 x 415/460 V, 50-60 Hz. Consumo 0,3 kW. Diametro de bobina máx. 370 mm.

Weight
345

CLOSED

Sold
97  -  Carton case sealer machine
500 €

Manufacturer
NEU 2M
Model
SYSTEMAIR

Weight
347

CLOSED

Manufacturer
NEU 2M
Model
SYSTEMAIR

Weight
347

CLOSED

Sold
98  -  Air treatment equipment
500 €

Manufacturer
THERMO EUROGLAS
Model
ELS 3000
No. Series
3417
Observations
The Thermo Electron ELS 3000 auto-sampler is designed for fully automated introduction of light hydrocarbon samples. The sampler has 74 positions for 2 ml screw capped sample vials and can inject a maximum of 250 µl. Key advantages of the ELS 3000 autosampler are: • Designed for a 24 hours operational environment • All operations fully controlled by Windows® (ThEuS) software • Easy connection to universal syringe type liquids or boat introduction modules • Wash solvent and waste containers included.

Weight
30

CLOSED

Manufacturer
THERMO EUROGLAS
Model
ELS 3000
No. Series
3417
Observations
The Thermo Electron ELS 3000 auto-sampler is designed for fully automated introduction of light hydrocarbon samples. The sampler has 74 positions for 2 ml screw capped sample vials and can inject a maximum of 250 µl. Key advantages of the ELS 3000 autosampler are: • Designed for a 24 hours operational environment • All operations fully controlled by Windows® (ThEuS) software • Easy connection to universal syringe type liquids or boat introduction modules • Wash solvent and waste containers included.

Weight
30

CLOSED

Sold
99  -  Auto Sampler
450 €

Manufacturer
ERLAB GROUP
Model
CAPTAIR FLEX M321
Year
2012
Observations
Ductless filtering fume hoods and vented storage cabinetsNumber of filtration columns 1 Number of fans (IP44) 1 Air flow rate 230 m3/h Air velocity at openings (in on-position) 0,4 to 0,6 m/s Voltage/frequency 90 - 264 V / 50 Hz Structure Anti-corrosion steel coated with acid-proof Panels 8 mm synthetic glass Filtration module Polypropylene. Dimensions: Interior: 764x540x860mm Exterior 800x620x1120mm.

Weight
72

CLOSED

Manufacturer
ERLAB GROUP
Model
CAPTAIR FLEX M321
Year
2012
Observations
Ductless filtering fume hoods and vented storage cabinetsNumber of filtration columns 1 Number of fans (IP44) 1 Air flow rate 230 m3/h Air velocity at openings (in on-position) 0,4 to 0,6 m/s Voltage/frequency 90 - 264 V / 50 Hz Structure Anti-corrosion steel coated with acid-proof Panels 8 mm synthetic glass Filtration module Polypropylene. Dimensions: Interior: 764x540x860mm Exterior 800x620x1120mm.

Weight
72

CLOSED

Manufacturer
METALCHEK
Observations
TECHNICAL DATA Electric frequency Hz 50 Voltage Volt 230 Max throughput Tablets/min 30.000 Detects ferrous contaminant up to mm 0.25 Non ferrous up to mm 0.3 Stainless steel up to mm 0.4 Dimensions mm 900 x 800 x 1630 Weight Kg 50

Weight
148

CLOSED

Manufacturer
METALCHEK
Observations
TECHNICAL DATA Electric frequency Hz 50 Voltage Volt 230 Max throughput Tablets/min 30.000 Detects ferrous contaminant up to mm 0.25 Non ferrous up to mm 0.3 Stainless steel up to mm 0.4 Dimensions mm 900 x 800 x 1630 Weight Kg 50

Weight
148

CLOSED

Manufacturer
LOMA SYSTEMS
Model
MICRO PH 2
Year
1996
No. Series
52829
Observations
PH Pharmaceutical Metal Detector is designed for inspecting tablets and capsules after the tablet and de-duster process with throughput of up to 30,000 units per minute.

Weight
300

CLOSED

Manufacturer
LOMA SYSTEMS
Model
MICRO PH 2
Year
1996
No. Series
52829
Observations
PH Pharmaceutical Metal Detector is designed for inspecting tablets and capsules after the tablet and de-duster process with throughput of up to 30,000 units per minute.

Weight
300

CLOSED

Manufacturer
PHASE TECHNOLOGY
Model
CPA-70V
No. Series
700010485

Weight
28

CLOSED

Manufacturer
PHASE TECHNOLOGY
Model
CPA-70V
No. Series
700010485

Weight
28

CLOSED

Manufacturer
METROHM
Model
716 DMS TITRINO
Observations
Specifications: - Voltage: 0 to 2000mV - Current: 0 to 200µA - Temperature: -150 to 450°C - Dimensions (W x H x D): 15 x 45 x 27.5 cm - Weight: 3.4 kg

Weight
33

CLOSED

Manufacturer
METROHM
Model
716 DMS TITRINO
Observations
Specifications: - Voltage: 0 to 2000mV - Current: 0 to 200µA - Temperature: -150 to 450°C - Dimensions (W x H x D): 15 x 45 x 27.5 cm - Weight: 3.4 kg

Weight
33

CLOSED

Manufacturer
METROHM
Model
716DMS TRITINO
No. Series
11140455
Observations
Specifications: - Voltage: 220/230/240V - Current: 0 to 200µA - Temperature: -150 to 450°C - Dimensions (W x H x D): 15 x 45 x 27.5 cm - Weight: 3.4 kg

Weight
35

CLOSED

Manufacturer
METROHM
Model
716DMS TRITINO
No. Series
11140455
Observations
Specifications: - Voltage: 220/230/240V - Current: 0 to 200µA - Temperature: -150 to 450°C - Dimensions (W x H x D): 15 x 45 x 27.5 cm - Weight: 3.4 kg

Weight
35

CLOSED

Manufacturer
DIONEX
Model
P580A LPG
No. Series
9931257
Observations
The Dionex P580 Pump is a high precision pump for the HPLC analysis. The patented isokinetic pre-compression allows a precise and zero-pulsation flow. With flow rates ranging from 1μl/min to 10ml/min (analytical version) and operating pressures up to 50.0 MPa (500 bar), the P580 is suitable for both regular and micro HPLC. Specifications: - Power requirements: 100V / 230V ±10%, 50/60Hz - Low-pressure gradient: quaternary - High-pressure gradient: binary (with optional "Solvent Selector": from 4 solvents). Flow gradient can be combined with solvent gradient - Standard mixing chamber volume: 0.2 ml

Weight
53

CLOSED

Manufacturer
DIONEX
Model
P580A LPG
No. Series
9931257
Observations
The Dionex P580 Pump is a high precision pump for the HPLC analysis. The patented isokinetic pre-compression allows a precise and zero-pulsation flow. With flow rates ranging from 1μl/min to 10ml/min (analytical version) and operating pressures up to 50.0 MPa (500 bar), the P580 is suitable for both regular and micro HPLC. Specifications: - Power requirements: 100V / 230V ±10%, 50/60Hz - Low-pressure gradient: quaternary - High-pressure gradient: binary (with optional "Solvent Selector": from 4 solvents). Flow gradient can be combined with solvent gradient - Standard mixing chamber volume: 0.2 ml

Weight
53

CLOSED

Manufacturer
DIONEX
Model
RF2000
Observations
Dionex Fluorescence Detector RF-2000 enhances productivity of analysis through its highest performance and stability. It supports operation via data system Chromeleon. Specifications: Light source: 150W xenon lamp Light source chamber: Ozone self dissolving type lamp house Monochromators: Ion brazed holographic concave diffraction grating monochromators F/2. 4 for both excitation and emission sides Number of grooves: 900 lines/mm Wavelength range: 200~650nm and 0 order Bandwidth: 15nm for both excitation and emission sides Wavelength accuracy: ±2nm Wavelength repeatability: ±0.2nm Wavelength scanning speed: SUPER, FAST, MEDIUM and SLOW, 4 steps SUPER: Approx. 3,000nm/min FAST: Approx. 600nm/min MEDIUM: Approx. 120nm/min SLOW: Approx. 24nm/min Wavelength moving speed: Approx. 15,000nm/min Detector: Signal side: Photomultiplier tube Monitor side: Photodiode Measuring method: Ratio compensation system with monochromatic light monitoring. Time constant: 0.1, 0.5, 1.5and 3s, 4 steps. Sensitivity: HIGH, MED and LOW, 3 steps (sensitivity difference is approx. 32 times) Gain: x1, x4, and x16, 3 steps (approx. 1 time, 4 times, and 16 times) Range: 1/∞ (0mV), x1, x1/2, x1/4, x1/8, x1/16, x1/32, x1/64, x1/128, x1/256 Output terminals: Recorder: 1mV, 10mV Integrator: 1V/FS Contact signal output (EVENT OUT output) Input terminals: Contact signal input (START input, STOP input) Cell: 12µl square quarts flow cell, pressure tolerance 1.96Mpa {20kgf/cm2 } (figure inside { } is reference.) Communication: Controllable by CHROMELEON via RS-232C Display unit: Fluorescent display tube Measuring function: * Monitor function Auto zero, Base line shift * Time program function Up to 32 steps can be programmed. * Wavelength scanning function Excitation and Emission wavelength scanning Differential spectrum Plot output

Weight
63

CLOSED

Manufacturer
DIONEX
Model
RF2000
Observations
Dionex Fluorescence Detector RF-2000 enhances productivity of analysis through its highest performance and stability. It supports operation via data system Chromeleon. Specifications: Light source: 150W xenon lamp Light source chamber: Ozone self dissolving type lamp house Monochromators: Ion brazed holographic concave diffraction grating monochromators F/2. 4 for both excitation and emission sides Number of grooves: 900 lines/mm Wavelength range: 200~650nm and 0 order Bandwidth: 15nm for both excitation and emission sides Wavelength accuracy: ±2nm Wavelength repeatability: ±0.2nm Wavelength scanning speed: SUPER, FAST, MEDIUM and SLOW, 4 steps SUPER: Approx. 3,000nm/min FAST: Approx. 600nm/min MEDIUM: Approx. 120nm/min SLOW: Approx. 24nm/min Wavelength moving speed: Approx. 15,000nm/min Detector: Signal side: Photomultiplier tube Monitor side: Photodiode Measuring method: Ratio compensation system with monochromatic light monitoring. Time constant: 0.1, 0.5, 1.5and 3s, 4 steps. Sensitivity: HIGH, MED and LOW, 3 steps (sensitivity difference is approx. 32 times) Gain: x1, x4, and x16, 3 steps (approx. 1 time, 4 times, and 16 times) Range: 1/∞ (0mV), x1, x1/2, x1/4, x1/8, x1/16, x1/32, x1/64, x1/128, x1/256 Output terminals: Recorder: 1mV, 10mV Integrator: 1V/FS Contact signal output (EVENT OUT output) Input terminals: Contact signal input (START input, STOP input) Cell: 12µl square quarts flow cell, pressure tolerance 1.96Mpa {20kgf/cm2 } (figure inside { } is reference.) Communication: Controllable by CHROMELEON via RS-232C Display unit: Fluorescent display tube Measuring function: * Monitor function Auto zero, Base line shift * Time program function Up to 32 steps can be programmed. * Wavelength scanning function Excitation and Emission wavelength scanning Differential spectrum Plot output

Weight
63

CLOSED

Subscribe to our Newsletter

Cookies Policy

We use our own and third-party cookies to obtain statistical data on the navigation of our users and improve our services.

Please note that if you accept third-party cookies, you will need to delete them from your browser settings or through the system provided by the third party itself.

Cerrar

Forgot Password?

Sign Up