No. of sale: 300621L
Starting dateManufacturerBÜCHI ModelB540 No. Series500662036580001 ObservationsMemory for 10 methods, user programmable.Temperature range: Room temperature up to 400°C Warm-up rate: 50°C-350°C max. 5 min. Cooling rate: 350°C-50°C max. 10 min. Measuring accuracy: up to 100°C ± 0.3°C' up to 250°C ± 0.5°C up to 400°C ± 0.8°C Mains voltage: 220-230 V/100-120 V, 50/60 Hz Power consumption: 200 W Interface: RS-232 Instrument dimensions (WxHxD): 170 x 210 x 340 mm Weight: 5.4 kg Weight14
ManufacturerBÜCHI ModelB540 No. Series500662036580001 ObservationsMemory for 10 methods, user programmable.Temperature range: Room temperature up to 400°C Warm-up rate: 50°C-350°C max. 5 min. Cooling rate: 350°C-50°C max. 10 min. Measuring accuracy: up to 100°C ± 0.3°C' up to 250°C ± 0.5°C up to 400°C ± 0.8°C Mains voltage: 220-230 V/100-120 V, 50/60 Hz Power consumption: 200 W Interface: RS-232 Instrument dimensions (WxHxD): 170 x 210 x 340 mm Weight: 5.4 kg Weight14
CLOSED
ManufacturerMETROHM Model730 ObservationsThe Metrohm 730 Sample Changer is an instrument for numerous applications. It was specially developed for the industrial or analytical laboratory and therefore covers a wide spectrum of applications. It provides indispensable support when processing a large sample series in the entire range of titrations, for various measurement jobs, or for dosing purposes. Due to the well-developed communication interfaces (parallel remote control and serial RS 232) it can not only communicate with the large palette of Metrohm titration and dosing instruments; it can also control or be controlled by any instrument that has a suitable communication interface Weight36
ManufacturerMETROHM Model730 ObservationsThe Metrohm 730 Sample Changer is an instrument for numerous applications. It was specially developed for the industrial or analytical laboratory and therefore covers a wide spectrum of applications. It provides indispensable support when processing a large sample series in the entire range of titrations, for various measurement jobs, or for dosing purposes. Due to the well-developed communication interfaces (parallel remote control and serial RS 232) it can not only communicate with the large palette of Metrohm titration and dosing instruments; it can also control or be controlled by any instrument that has a suitable communication interface Weight36
CLOSED
ManufacturerVITEK 2 Model2 ObservationsVITEK 2 is a fully automated system that performs bacterial identification and antibiotic susceptibility testing. Weight: VITEK 2 (60 card capacity): 110 kgElectrical Power Requirements: 110/120 VAC (50-60 Hz) 220/240 VAC (50-60 Hz) Heat Dissipated: VITEK® 2: 512 BTU/Hr. (nominal) Weight44
ManufacturerVITEK 2 Model2 ObservationsVITEK 2 is a fully automated system that performs bacterial identification and antibiotic susceptibility testing. Weight: VITEK 2 (60 card capacity): 110 kgElectrical Power Requirements: 110/120 VAC (50-60 Hz) 220/240 VAC (50-60 Hz) Heat Dissipated: VITEK® 2: 512 BTU/Hr. (nominal) Weight44
CLOSED
ManufacturerGRANULOSHOP ModelDENSITAP ETD-20 Observationsstandard 250 ml cylinder. .220/110 50/60 Hz Weight58
ManufacturerGRANULOSHOP ModelDENSITAP ETD-20 Observationsstandard 250 ml cylinder. .220/110 50/60 Hz Weight58
CLOSED
ManufacturerDIONEX ModelUVD170S No. Series1180008 ObservationsSpecifications Optics Single beam principle with simultaneous measurement across the photodiode array Light source Deuterium lamp Wavelength range 200nm - 344nm (UV-range) 345nm - 595nm (VIS-range) Pixel bandwidth 1.9nm (UV-range) 3.3nm (VIS-range) Wavelength accuracy ± 0.75nm (UV-range) ± 1.5nm (VIS-range) Noise < ± 0.8 x 10-5AU, after 3h warm-up at 254nm, time step 1sec., empty flow cell Drift < 5 x 10-4AU/h, after 3h warm-up at 254nm, empty flow cell Flow cell volume Standard flow cell: 10µl, 9mm path Standard flow cell/PEEK capillaries: 10µl, 9mm path Preparative flow cell: 6µl, 2mm path Micro capillary flow cell: 0.14µl, 8mm path Flow cell pressure rating Standard flow cell: 100bar (10,000kPa) Standard flow cell/PEEK cap. 100bar (10,000kPa) Preparative flow cell: 100bar (10,000kPa) Micro capillary flow cell: 400bar (40,000kPa) Measuring range 0AU to 2AU Weight66
ManufacturerDIONEX ModelUVD170S No. Series1180008 ObservationsSpecifications Optics Single beam principle with simultaneous measurement across the photodiode array Light source Deuterium lamp Wavelength range 200nm - 344nm (UV-range) 345nm - 595nm (VIS-range) Pixel bandwidth 1.9nm (UV-range) 3.3nm (VIS-range) Wavelength accuracy ± 0.75nm (UV-range) ± 1.5nm (VIS-range) Noise < ± 0.8 x 10-5AU, after 3h warm-up at 254nm, time step 1sec., empty flow cell Drift < 5 x 10-4AU/h, after 3h warm-up at 254nm, empty flow cell Flow cell volume Standard flow cell: 10µl, 9mm path Standard flow cell/PEEK capillaries: 10µl, 9mm path Preparative flow cell: 6µl, 2mm path Micro capillary flow cell: 0.14µl, 8mm path Flow cell pressure rating Standard flow cell: 100bar (10,000kPa) Standard flow cell/PEEK cap. 100bar (10,000kPa) Preparative flow cell: 100bar (10,000kPa) Micro capillary flow cell: 400bar (40,000kPa) Measuring range 0AU to 2AU Weight66
CLOSED
ManufacturerTHERMO ModelULTIMATE 3000 Year2013 No. Series50359200 ObservationsSolvent reservoir capacity: Eight 1-L reservoirs or four 2.5-L reservoirs or two 5-L reservoirs or five 1-L reservoirs and one 5-L reservoir or three 2.5L and two 1-L reservoirs or three 1-L and two 2.5-L reservoirs or sixteen 0.5L reservoirs Wetted parts: PEEK™, FEP, and ETFE/ECTFE Inline filter frit: SST, PEEK, or Titanium Environmental conditions: Range of use: Indoor use Temperature: 10 °C to 35°C Air humidity: max. 80% rel. humidity, non-condensing Pollution degree: 2 Dimensions (h x w x d): 10 x 42 x 51 cm Emission sound pressure level: No emission Weight: 3.0 kg without reservoirs Weight67
ManufacturerTHERMO ModelULTIMATE 3000 Year2013 No. Series50359200 ObservationsSolvent reservoir capacity: Eight 1-L reservoirs or four 2.5-L reservoirs or two 5-L reservoirs or five 1-L reservoirs and one 5-L reservoir or three 2.5L and two 1-L reservoirs or three 1-L and two 2.5-L reservoirs or sixteen 0.5L reservoirs Wetted parts: PEEK™, FEP, and ETFE/ECTFE Inline filter frit: SST, PEEK, or Titanium Environmental conditions: Range of use: Indoor use Temperature: 10 °C to 35°C Air humidity: max. 80% rel. humidity, non-condensing Pollution degree: 2 Dimensions (h x w x d): 10 x 42 x 51 cm Emission sound pressure level: No emission Weight: 3.0 kg without reservoirs Weight67
CLOSED