No. of sale: 300621L
Starting dateManufacturerGARDNER DENVER ObservationsTank Capacity: 500Lt Weight363
ManufacturerGARDNER DENVER ObservationsTank Capacity: 500Lt Weight363
CLOSED
ManufacturerAGILENT/ HEWLETT PACKARD ModelHP 6890 ObservationsSpecifications: Data communications HP-IB, RS-232-C, and two analog output channels (1-mV, 1-V, and 10-V output available) as standard INET interface optional Heated zones Independent heated zones, not including oven: six (two inlets, two detectors, and two auxiliary) Maximum operating temperatures for auxiliary zones: 400° C Column oven Operating temperature: 4° C above ambient to 450° C Temperature setpoint resolution: 1° C Maximum run time: 999.99 min Programming ramps/plateaus: 6/7 Inlets All inlets include septum purge. Split/splitless: electronic flow, 400° C max, electronic entry of pressure or flow and split ratio version. Pressure setting range: 0-100 psi Total flow setting range: split/splitless, 0-200 ml/min N2, 0-1000 ml/min H2 or He Detectors: All detectors include electronic on/off of all detector gases. FID 450° C maximum operating temperature Automatic flame ignition from the keypad or ChemStation Flame out detection MDL: <5 pg carbon/s as propane using N2 carrier and 0.2794-mm jet Linear dynamic range: < 10%, 107 with N2 carrier and 0.2794-mm jet NPD 400° C maximum operating temperature Automatic baseline adjusting via keypad or ChemStation MDL: <0.4 pg N/s, <0.2 pg P/s with azobenzene/malathion mixture Selectivity: 35000 to 1 gN/gC, 75000 to 1 gP/gC with azobenzene/malathion/ octadecane Dynamic range: >105 N >105 P with azobenzene/malathion mixture TCD 400° C maximum operating temperature Single filament with microcell MDL: <400 pg propane/ml He caxrier (MDL may be affected by laboratory environment.) Linear dynamic range: 105 (5%) ECD Equipped with anode purge for contamination resistance 400° C maximum operating temperature Makeup gas types: argon (5%)/methane, nitrogen Radioactive source: 15 mCi 63Ni plated MDL: <0.04 pg/s lindane Dynamic range: > 104 with lindane Weight3
ManufacturerAGILENT/ HEWLETT PACKARD ModelHP 6890 ObservationsSpecifications: Data communications HP-IB, RS-232-C, and two analog output channels (1-mV, 1-V, and 10-V output available) as standard INET interface optional Heated zones Independent heated zones, not including oven: six (two inlets, two detectors, and two auxiliary) Maximum operating temperatures for auxiliary zones: 400° C Column oven Operating temperature: 4° C above ambient to 450° C Temperature setpoint resolution: 1° C Maximum run time: 999.99 min Programming ramps/plateaus: 6/7 Inlets All inlets include septum purge. Split/splitless: electronic flow, 400° C max, electronic entry of pressure or flow and split ratio version. Pressure setting range: 0-100 psi Total flow setting range: split/splitless, 0-200 ml/min N2, 0-1000 ml/min H2 or He Detectors: All detectors include electronic on/off of all detector gases. FID 450° C maximum operating temperature Automatic flame ignition from the keypad or ChemStation Flame out detection MDL: <5 pg carbon/s as propane using N2 carrier and 0.2794-mm jet Linear dynamic range: < 10%, 107 with N2 carrier and 0.2794-mm jet NPD 400° C maximum operating temperature Automatic baseline adjusting via keypad or ChemStation MDL: <0.4 pg N/s, <0.2 pg P/s with azobenzene/malathion mixture Selectivity: 35000 to 1 gN/gC, 75000 to 1 gP/gC with azobenzene/malathion/ octadecane Dynamic range: >105 N >105 P with azobenzene/malathion mixture TCD 400° C maximum operating temperature Single filament with microcell MDL: <400 pg propane/ml He caxrier (MDL may be affected by laboratory environment.) Linear dynamic range: 105 (5%) ECD Equipped with anode purge for contamination resistance 400° C maximum operating temperature Makeup gas types: argon (5%)/methane, nitrogen Radioactive source: 15 mCi 63Ni plated MDL: <0.04 pg/s lindane Dynamic range: > 104 with lindane Weight3
CLOSED
ManufacturerPESTER PACK ModelPEWO-PACK250 Year2005 ObservationsMin./ max format range of collation: - 60 x 30 x 60 mm / 360 x 180 x 250 mm Length: 1.100 - 1.900 mm Width: 1.050 mm Height: 1.750 mm Max. film width processed: 250 mm Max. format range: 180 x 400 x 200 mm Performance: 60 cycles /min (collations /min) Material: Polyethylene Control: Elau Weight225
ManufacturerPESTER PACK ModelPEWO-PACK250 Year2005 ObservationsMin./ max format range of collation: - 60 x 30 x 60 mm / 360 x 180 x 250 mm Length: 1.100 - 1.900 mm Width: 1.050 mm Height: 1.750 mm Max. film width processed: 250 mm Max. format range: 180 x 400 x 200 mm Performance: 60 cycles /min (collations /min) Material: Polyethylene Control: Elau Weight225
CLOSED
No. SeriesInternal reference 350 ObservationsOil capsule machines bath
No. SeriesInternal reference 350 ObservationsOil capsule machines bath
CLOSED
ManufacturerFedegari ModelFVA3/A1 Year2005 ObservationsAutoclave, Useful capacity: 140lt, chamber type: vertical with cylindrical creoss-section, chamber diameter: 500mm, useful height: 700mm, weight when empty: 175kg, weight when filled with water: 340kg, loading height: 875mm, external dimensions: WxHxD: 1200x1305x600mm, presión máx.: 3bar, 10.5A, 400V, 50Hz, 3ph. Weight6
ManufacturerFedegari ModelFVA3/A1 Year2005 ObservationsAutoclave, Useful capacity: 140lt, chamber type: vertical with cylindrical creoss-section, chamber diameter: 500mm, useful height: 700mm, weight when empty: 175kg, weight when filled with water: 340kg, loading height: 875mm, external dimensions: WxHxD: 1200x1305x600mm, presión máx.: 3bar, 10.5A, 400V, 50Hz, 3ph. Weight6
CLOSED
ManufacturerL.B. BOHLE ModelK.A.120 Year1995 ObservationsControl Device For Dragees And Film-Coated Tablets, Weight273
ManufacturerL.B. BOHLE ModelK.A.120 Year1995 ObservationsControl Device For Dragees And Film-Coated Tablets, Weight273
CLOSED
ManufacturerThermo Scientific ModelSOLAAR S Series AA - FS/GF95 ObservationsThe S Series of spectrometers offer no-compromise, single atomizer, multi-element AA systems, all in a footprint of less than 0.5 sq. m. A new Ebert optical system covers the range 185nm to 760nm as standard, with an optional wide range PMT up to 900nm, and sets new levels of performance. The standard 6 lamp auto-aligning turret (using data-coded or uncoded lamps, each with its own power supply) and Stockdale double beam system combine to produce excellent results. QuadLine deuterium background correction is standard on all units. Universal 50mm titanium burner supports all flame types and has high solids handling, excellent flame stability and low carbon build-up. Auto-optimising software control of burner height adjustment. Standard inert fluoroplastic spray chamber, with adjustable impact bead, and inert nebulizer provide unmatched sensitivity. Automatic binary flow gas management in the S4 model (or the semi-automatic version in the S2) guarantees reproducibility and safety. Feature-packed Windows 98/2000/XP-compatible SOLAAR software control offers multiple wizards to optimise system parameters and control analyses. Optional LCD Local Control available. Full range of optional accessories to provide an optimal solution to a wide range of analysis types, including flame autosamplers, graphite furnace and vapour analyses. Weight4
ManufacturerThermo Scientific ModelSOLAAR S Series AA - FS/GF95 ObservationsThe S Series of spectrometers offer no-compromise, single atomizer, multi-element AA systems, all in a footprint of less than 0.5 sq. m. A new Ebert optical system covers the range 185nm to 760nm as standard, with an optional wide range PMT up to 900nm, and sets new levels of performance. The standard 6 lamp auto-aligning turret (using data-coded or uncoded lamps, each with its own power supply) and Stockdale double beam system combine to produce excellent results. QuadLine deuterium background correction is standard on all units. Universal 50mm titanium burner supports all flame types and has high solids handling, excellent flame stability and low carbon build-up. Auto-optimising software control of burner height adjustment. Standard inert fluoroplastic spray chamber, with adjustable impact bead, and inert nebulizer provide unmatched sensitivity. Automatic binary flow gas management in the S4 model (or the semi-automatic version in the S2) guarantees reproducibility and safety. Feature-packed Windows 98/2000/XP-compatible SOLAAR software control offers multiple wizards to optimise system parameters and control analyses. Optional LCD Local Control available. Full range of optional accessories to provide an optimal solution to a wide range of analysis types, including flame autosamplers, graphite furnace and vapour analyses. Weight4
CLOSED
ManufacturerPERKIN ELMER ModelOPTIMA 2000DV No. Series2072 ObservationsThe PerkinElmer OPTIMA 2000 optical emission spectrometer is a compact, bench-mounted, high-speed scanningCCD-based sequential ICP-OES system. All systems feature dual viewing of the plasma; a free-running 40-MHz solid-stateRF generator; a double monochromator; and a dual backside-illuminated charge-coupled device (DBI-CCD) detector. SPECTROMETER SPECIFICATIONS Double monochromator The OPTIMA 2000 ICP-OES uses a unique double-monochromator optical system.The first, or preselection monochromator, selects a small portion of the spectrum around the analytical line of interest.The second, the Echelle-based highdispersion monochromator, disperses the narrow wavelength range onto the DBI-CCD.This unique design results in a highspeed, high light-throughput optical system offering excellent resolution, all in a compact system.The entire system is shockmounted so that normal floor vibrations do not affect system performance.The sealed optical system can be purged with nitrogen for low UV (<190 nm) performance. Preselection monochromator The preselection monochromator has a focal length of 0.3 meter and uses a Stigmatic Littrow configuration. The disperser is a 30-degree CaF2 prism. Echelle monochromator The high-dispersion Echelle monochromator also has a focal length of 0.3 meter and a Stigmatic Littrow configuration.The Echelle grating used for dispersion has 79 lines/mm with a blaze angle of 63.8 degrees. Spectrometer parameters The spectral range is 160-900 nm. The slew rate is less than 3 seconds to cover the spectral range, and the measured resolution is <0.009 nm @ 200 nm.The prism and Echelle grating are rotated less than ± 2 degrees to accessany wavelength, dramatically improving analytical speed. Plasma viewing The dual-view optics of the OPTIMA 2000 ICP-OES allow the plasma to be viewed radially or axially. Dual viewing of the plasma provides the best possible combination, allowing for trace and major levels of an element to be determined without having to do extensive methods development at several alternate wavelengths.The OPTIMA 2000 software allows the selection of axial or radial viewing with automatic adjustment of the plasma viewing in both the vertical and horizontal direction. Detector The UV-sensitive, dual backside-illuminated CCD detector is cooled directly using a single-stage integrated Peltier cooler operated at approximately -8°C.The detector housing is hermetically sealed and is filled with dry nitrogen to eliminatecondensation.The detector has two photosensitive segments containing 176 by 128 pixels. One section is used for analytical measurements, and the other is a wavelength reference section.The solid-state detector collects both the analyte spectra and the nearby background spectra, allowing for simultaneous background correction and providing improved precision and analytical speed. Dynamic wavelength correction The wavelength reference section monitors a full wavelength neon spectrum, creating a dynamic wavelength scale used to actively correct wavelength positions.The resulting wavelength accuracy and reproducibility allows direct correction ‘on-peak’ measurements rather than time-consuming peak-search methods used in sequential ICP systems. ICP SYSTEM SPECIFICATIONS RF generator and coil The OPTIMA 2000 ICP-OES features a 40-MHz, free-running, solid-state (no power amplifier tube needed) RF generator, adjustable from 750 to 1500 watts, in 1-watt increments.The power efficiency is greater than 75% with <0.1% variation in output power stability.The solid-state components significantly increase reliability and can result in higher signal/power readings than conventional tube generators.The compact RF supply meets all FCC certification requirements for RF emission (Part 18 of FCC Rules and Regulations). It also complies with EC and VDE 0871 Class B requirements. Ignition and power control Plasma ignition is computer-controlled and totally automated. A unique software feature allows the plasma to be ignited automatically at a user-determined time to warm up the system prior to an analysis.The plasma can be turned off automatically after an analysis.True power control maintains the plasma power, even when changing sample matrices. Safety interlocks For user safety and system protection, the system constantly monitors water flow, shear gas pressure, argon pressure, sample compartment door closure and plasma stability, and displays the interlock status on the computer screen asgraphic symbols. If an interlock is interrupted, the plasma will automatically shut down safely. Cooling water A water recirculating cooling system is required, with approximately 4 L/min flow capacity at 310 to 550 kPa and atemperature between 15°C and 25°C.A NESLAB CFT 75D or equivalent is recommended. GAS FLOW CONTROLS Argon flow Computer-controlled solenoid valves are used to regulate the flow automatically within the range of 0-20 L/minin 1-L/min increments for plasma argon and 0 to 2.0 L/min in 0.1-L/min increments for auxiliary argon. A mass flow controller is supplied with all systems for the nebulizer argon flow and is variable between 0 and 2.0 L/min in 0.01-L/min increments. Shear gas A compressed air shear gas (18-25 L/min) is used to remove the plasma tail from the optical path, minimizing interferencesand extending the dynamic range.The shear gas design offers a maintenance-free and lower-cost (no use ofArgon) approach to removing the cooler plasma zone. SAMPLE INTRODUCTION SYSTEM Torch A unique, demountable torch design using one-piece quartz tubing for plasma and auxiliary gas flow is supplied.The standard torch includes a 2.0-mm i.d. alumina injector for full corrosion resistance to all acids, including hydrofluoric and aqua regia. A variety of other injectors are available. Torch mount The OPTIMA 2000 ICP-OES features a unique, externally mounted spray chamber. The mount can be adjusted (with theplasma on) for maximum performance in different matrices. Unlike other external spray chambers, which can drift with room temperature, the OPTIMA 2000 torch mount is enclosed in a thermally controlled area outside of the torch compartment. No tools are required for torch or sample introduction removal. Spray chamber The OPTIMA 2000 offers multiple sample introduction systems for complete flexibility.The standard Scott spray chamber is made from inert carbon-filled polyphenylene sulfide (PPS) for complete corrosion resistance to most acids, including HF. A glass cyclonic spray chamber is available and is typically used for high-performance trace elemental analyses. Nebulizer Both a cross-flow and a concentric nebulizer are available.The GemTip™ cross-flow nebulizer is manufactured from corrosion-resistant materials [sapphire/ruby tips in a polyetheretherketone (PEEK) body].The system can routinely handle 50% (v/v) solutions of HCl, HNO3, H2SO4, H3PO4, 20% (v/v) HF and 30% (w/v) NaOH. The system is fully compatible with other sample introduction devices such as ultrasonics, concentrics, and spark ablation. Peristaltic pump The three-channel, computer-controlled pump has variable speeds from 0.2 to 5 mL/min in 0.1-mL/min increments, using 0.76-mm (0.030 in.) i.d. tubing. Software features include FastPump™ and SmartRinse™, which dramatically improve the sample rinse-out and analysis times. Spares kit A spares kit, which includes an assortment of commonly required replacement items and consumables, is included withall Optima™ systems. PerkinElmer offers a complete range of accessories for the OPTIMA 2000. SYSTEM SPECIFICATIONS Power 200-240 VAC, 30A , single phase, 50/60 Hz (±1%) Dimensions 132 cm wide x 81 cm high x 76 cm deep Weight 125 kg Environmental The instrument will operate with a laboratory temperature between 15 and 35 °C (59 - 95 °F). For optimum instrumentperformance, the room temperature should be controlled at 20 ±2 °C Weight8
ManufacturerPERKIN ELMER ModelOPTIMA 2000DV No. Series2072 ObservationsThe PerkinElmer OPTIMA 2000 optical emission spectrometer is a compact, bench-mounted, high-speed scanningCCD-based sequential ICP-OES system. All systems feature dual viewing of the plasma; a free-running 40-MHz solid-stateRF generator; a double monochromator; and a dual backside-illuminated charge-coupled device (DBI-CCD) detector. SPECTROMETER SPECIFICATIONS Double monochromator The OPTIMA 2000 ICP-OES uses a unique double-monochromator optical system.The first, or preselection monochromator, selects a small portion of the spectrum around the analytical line of interest.The second, the Echelle-based highdispersion monochromator, disperses the narrow wavelength range onto the DBI-CCD.This unique design results in a highspeed, high light-throughput optical system offering excellent resolution, all in a compact system.The entire system is shockmounted so that normal floor vibrations do not affect system performance.The sealed optical system can be purged with nitrogen for low UV (<190 nm) performance. Preselection monochromator The preselection monochromator has a focal length of 0.3 meter and uses a Stigmatic Littrow configuration. The disperser is a 30-degree CaF2 prism. Echelle monochromator The high-dispersion Echelle monochromator also has a focal length of 0.3 meter and a Stigmatic Littrow configuration.The Echelle grating used for dispersion has 79 lines/mm with a blaze angle of 63.8 degrees. Spectrometer parameters The spectral range is 160-900 nm. The slew rate is less than 3 seconds to cover the spectral range, and the measured resolution is <0.009 nm @ 200 nm.The prism and Echelle grating are rotated less than ± 2 degrees to accessany wavelength, dramatically improving analytical speed. Plasma viewing The dual-view optics of the OPTIMA 2000 ICP-OES allow the plasma to be viewed radially or axially. Dual viewing of the plasma provides the best possible combination, allowing for trace and major levels of an element to be determined without having to do extensive methods development at several alternate wavelengths.The OPTIMA 2000 software allows the selection of axial or radial viewing with automatic adjustment of the plasma viewing in both the vertical and horizontal direction. Detector The UV-sensitive, dual backside-illuminated CCD detector is cooled directly using a single-stage integrated Peltier cooler operated at approximately -8°C.The detector housing is hermetically sealed and is filled with dry nitrogen to eliminatecondensation.The detector has two photosensitive segments containing 176 by 128 pixels. One section is used for analytical measurements, and the other is a wavelength reference section.The solid-state detector collects both the analyte spectra and the nearby background spectra, allowing for simultaneous background correction and providing improved precision and analytical speed. Dynamic wavelength correction The wavelength reference section monitors a full wavelength neon spectrum, creating a dynamic wavelength scale used to actively correct wavelength positions.The resulting wavelength accuracy and reproducibility allows direct correction ‘on-peak’ measurements rather than time-consuming peak-search methods used in sequential ICP systems. ICP SYSTEM SPECIFICATIONS RF generator and coil The OPTIMA 2000 ICP-OES features a 40-MHz, free-running, solid-state (no power amplifier tube needed) RF generator, adjustable from 750 to 1500 watts, in 1-watt increments.The power efficiency is greater than 75% with <0.1% variation in output power stability.The solid-state components significantly increase reliability and can result in higher signal/power readings than conventional tube generators.The compact RF supply meets all FCC certification requirements for RF emission (Part 18 of FCC Rules and Regulations). It also complies with EC and VDE 0871 Class B requirements. Ignition and power control Plasma ignition is computer-controlled and totally automated. A unique software feature allows the plasma to be ignited automatically at a user-determined time to warm up the system prior to an analysis.The plasma can be turned off automatically after an analysis.True power control maintains the plasma power, even when changing sample matrices. Safety interlocks For user safety and system protection, the system constantly monitors water flow, shear gas pressure, argon pressure, sample compartment door closure and plasma stability, and displays the interlock status on the computer screen asgraphic symbols. If an interlock is interrupted, the plasma will automatically shut down safely. Cooling water A water recirculating cooling system is required, with approximately 4 L/min flow capacity at 310 to 550 kPa and atemperature between 15°C and 25°C.A NESLAB CFT 75D or equivalent is recommended. GAS FLOW CONTROLS Argon flow Computer-controlled solenoid valves are used to regulate the flow automatically within the range of 0-20 L/minin 1-L/min increments for plasma argon and 0 to 2.0 L/min in 0.1-L/min increments for auxiliary argon. A mass flow controller is supplied with all systems for the nebulizer argon flow and is variable between 0 and 2.0 L/min in 0.01-L/min increments. Shear gas A compressed air shear gas (18-25 L/min) is used to remove the plasma tail from the optical path, minimizing interferencesand extending the dynamic range.The shear gas design offers a maintenance-free and lower-cost (no use ofArgon) approach to removing the cooler plasma zone. SAMPLE INTRODUCTION SYSTEM Torch A unique, demountable torch design using one-piece quartz tubing for plasma and auxiliary gas flow is supplied.The standard torch includes a 2.0-mm i.d. alumina injector for full corrosion resistance to all acids, including hydrofluoric and aqua regia. A variety of other injectors are available. Torch mount The OPTIMA 2000 ICP-OES features a unique, externally mounted spray chamber. The mount can be adjusted (with theplasma on) for maximum performance in different matrices. Unlike other external spray chambers, which can drift with room temperature, the OPTIMA 2000 torch mount is enclosed in a thermally controlled area outside of the torch compartment. No tools are required for torch or sample introduction removal. Spray chamber The OPTIMA 2000 offers multiple sample introduction systems for complete flexibility.The standard Scott spray chamber is made from inert carbon-filled polyphenylene sulfide (PPS) for complete corrosion resistance to most acids, including HF. A glass cyclonic spray chamber is available and is typically used for high-performance trace elemental analyses. Nebulizer Both a cross-flow and a concentric nebulizer are available.The GemTip™ cross-flow nebulizer is manufactured from corrosion-resistant materials [sapphire/ruby tips in a polyetheretherketone (PEEK) body].The system can routinely handle 50% (v/v) solutions of HCl, HNO3, H2SO4, H3PO4, 20% (v/v) HF and 30% (w/v) NaOH. The system is fully compatible with other sample introduction devices such as ultrasonics, concentrics, and spark ablation. Peristaltic pump The three-channel, computer-controlled pump has variable speeds from 0.2 to 5 mL/min in 0.1-mL/min increments, using 0.76-mm (0.030 in.) i.d. tubing. Software features include FastPump™ and SmartRinse™, which dramatically improve the sample rinse-out and analysis times. Spares kit A spares kit, which includes an assortment of commonly required replacement items and consumables, is included withall Optima™ systems. PerkinElmer offers a complete range of accessories for the OPTIMA 2000. SYSTEM SPECIFICATIONS Power 200-240 VAC, 30A , single phase, 50/60 Hz (±1%) Dimensions 132 cm wide x 81 cm high x 76 cm deep Weight 125 kg Environmental The instrument will operate with a laboratory temperature between 15 and 35 °C (59 - 95 °F). For optimum instrumentperformance, the room temperature should be controlled at 20 ±2 °C Weight8
CLOSED
ManufacturerPHARMA TECHNOLOGIC - LOCK ModelMET 30+ No. Series17498 ObservationsThe metal detector can detect and reject microscopic contaminants in pharmaceutical production lines, such as tiny lengths of sieve mesh and press tooling fragments, at speeds of up to 30,000 tablets per minute. Weight215
ManufacturerPHARMA TECHNOLOGIC - LOCK ModelMET 30+ No. Series17498 ObservationsThe metal detector can detect and reject microscopic contaminants in pharmaceutical production lines, such as tiny lengths of sieve mesh and press tooling fragments, at speeds of up to 30,000 tablets per minute. Weight215
CLOSED
ManufacturerIPROCOMSA Model500LT ObservationsCapacity tanks: 500Lts Weight283
ManufacturerIPROCOMSA Model500LT ObservationsCapacity tanks: 500Lts Weight283
CLOSED
ManufacturerMETTLET TOLEDO ModelIND890 ObservationsThanks to its standard touch screen, the IND890 is easy and reliable to operate even in the harshest environments, with IP69k protection. The application terminal also sets new standards in extremely complex weighing processes. It provides the perfect connection between a PC and a scale and the company network. With Windows operating system it can be used as a PC for aggressive areas having the optional ability to interface with scales or weighing system. Weight341
ManufacturerMETTLET TOLEDO ModelIND890 ObservationsThanks to its standard touch screen, the IND890 is easy and reliable to operate even in the harshest environments, with IP69k protection. The application terminal also sets new standards in extremely complex weighing processes. It provides the perfect connection between a PC and a scale and the company network. With Windows operating system it can be used as a PC for aggressive areas having the optional ability to interface with scales or weighing system. Weight341
CLOSED
ManufacturerVarian ModelCP3800 ObservationsThe Gas Chromatograph meets all your analytical requirements with practical solutions for simple and complex applications. In a standard configuration, the CP-3800 accommodates up to three injectors and three detectors, all operating simultaneously. In addition, the CP-3800 is easily configured to perform on-line analyses for monitoring critical gas and liquid process streams. The CP-3800’s flexible platform lets you start with a basic configuration and add a wide variety of options in the field. Options include additional channels, gas and liquid sampling valves, and external sampling devices. Weight5
ManufacturerVarian ModelCP3800 ObservationsThe Gas Chromatograph meets all your analytical requirements with practical solutions for simple and complex applications. In a standard configuration, the CP-3800 accommodates up to three injectors and three detectors, all operating simultaneously. In addition, the CP-3800 is easily configured to perform on-line analyses for monitoring critical gas and liquid process streams. The CP-3800’s flexible platform lets you start with a basic configuration and add a wide variety of options in the field. Options include additional channels, gas and liquid sampling valves, and external sampling devices. Weight5
CLOSED
ManufacturerSYSTEC ModelDX-45 ObservationsDimensions of useful capacity Ø x depth in mm 344 x 500, Volume of useful capacity in total / nominal liters 50/45. External dimensions in mm Height 585. Width 620. Depth 755. Net weight (kg) 105. Heating power kW 3,5. Weight46
ManufacturerSYSTEC ModelDX-45 ObservationsDimensions of useful capacity Ø x depth in mm 344 x 500, Volume of useful capacity in total / nominal liters 50/45. External dimensions in mm Height 585. Width 620. Depth 755. Net weight (kg) 105. Heating power kW 3,5. Weight46
CLOSED
ManufacturerI.RAND-MASTERIA ModelUP5-15-75/Masteria Year2005 No. Series2191315 ObservationsPower: 15kW. 7,5bar. 1470rev/min. With Tank 500Lt, and dryer Masteria. Weight241
ManufacturerI.RAND-MASTERIA ModelUP5-15-75/Masteria Year2005 No. Series2191315 ObservationsPower: 15kW. 7,5bar. 1470rev/min. With Tank 500Lt, and dryer Masteria. Weight241
CLOSED