Gutinvest

Lots

Pharma and laboratory equipment

No. of sale: 300621L

Starting date
25/05/2021 14:00:00
Closing Date
30/06/2021 14:00:00
Viewing days
by appointment
Location
Gerona - Spain
Online auction of more than 350 lots, belonging to the pharmaceutical and biotechnology sector. We highlight tablet counters, encapsulators, packaging machines, cartoning machines, autoclaves, gas chromatographs, metal detectors, laminar flow cabinets, pipettes ...
Sales commission
18% buyers premium
Payment methods

Manufacturer
GARDNER DENVER
Observations
Tank Capacity: 500Lt

Weight
363

CLOSED

Manufacturer
GARDNER DENVER
Observations
Tank Capacity: 500Lt

Weight
363

CLOSED

Sold
17  -  Mixer laboratory equipment
5.000 €

Manufacturer
AGILENT/ HEWLETT PACKARD
Model
HP 6890
Observations
Specifications: Data communications HP-IB, RS-232-C, and two analog output channels (1-mV, 1-V, and 10-V output available) as standard INET interface optional Heated zones Independent heated zones, not including oven: six (two inlets, two detectors, and two auxiliary) Maximum operating temperatures for auxiliary zones: 400° C Column oven Operating temperature: 4° C above ambient to 450° C Temperature setpoint resolution: 1° C Maximum run time: 999.99 min Programming ramps/plateaus: 6/7 Inlets All inlets include septum purge. Split/splitless: electronic flow, 400° C max, electronic entry of pressure or flow and split ratio version. Pressure setting range: 0-100 psi Total flow setting range: split/splitless, 0-200 ml/min N2, 0-1000 ml/min H2 or He Detectors: All detectors include electronic on/off of all detector gases. FID 450° C maximum operating temperature Automatic flame ignition from the keypad or ChemStation Flame out detection MDL: <5 pg carbon/s as propane using N2 carrier and 0.2794-mm jet Linear dynamic range: < 10%, 107 with N2 carrier and 0.2794-mm jet NPD 400° C maximum operating temperature Automatic baseline adjusting via keypad or ChemStation MDL: <0.4 pg N/s, <0.2 pg P/s with azobenzene/malathion mixture Selectivity: 35000 to 1 gN/gC, 75000 to 1 gP/gC with azobenzene/malathion/ octadecane Dynamic range: >105 N >105 P with azobenzene/malathion mixture TCD 400° C maximum operating temperature Single filament with microcell MDL: <400 pg propane/ml He caxrier (MDL may be affected by laboratory environment.) Linear dynamic range: 105 (5%) ECD Equipped with anode purge for contamination resistance 400° C maximum operating temperature Makeup gas types: argon (5%)/methane, nitrogen Radioactive source: 15 mCi 63Ni plated MDL: <0.04 pg/s lindane Dynamic range: > 104 with lindane

Weight
3

CLOSED

Manufacturer
AGILENT/ HEWLETT PACKARD
Model
HP 6890
Observations
Specifications: Data communications HP-IB, RS-232-C, and two analog output channels (1-mV, 1-V, and 10-V output available) as standard INET interface optional Heated zones Independent heated zones, not including oven: six (two inlets, two detectors, and two auxiliary) Maximum operating temperatures for auxiliary zones: 400° C Column oven Operating temperature: 4° C above ambient to 450° C Temperature setpoint resolution: 1° C Maximum run time: 999.99 min Programming ramps/plateaus: 6/7 Inlets All inlets include septum purge. Split/splitless: electronic flow, 400° C max, electronic entry of pressure or flow and split ratio version. Pressure setting range: 0-100 psi Total flow setting range: split/splitless, 0-200 ml/min N2, 0-1000 ml/min H2 or He Detectors: All detectors include electronic on/off of all detector gases. FID 450° C maximum operating temperature Automatic flame ignition from the keypad or ChemStation Flame out detection MDL: <5 pg carbon/s as propane using N2 carrier and 0.2794-mm jet Linear dynamic range: < 10%, 107 with N2 carrier and 0.2794-mm jet NPD 400° C maximum operating temperature Automatic baseline adjusting via keypad or ChemStation MDL: <0.4 pg N/s, <0.2 pg P/s with azobenzene/malathion mixture Selectivity: 35000 to 1 gN/gC, 75000 to 1 gP/gC with azobenzene/malathion/ octadecane Dynamic range: >105 N >105 P with azobenzene/malathion mixture TCD 400° C maximum operating temperature Single filament with microcell MDL: <400 pg propane/ml He caxrier (MDL may be affected by laboratory environment.) Linear dynamic range: 105 (5%) ECD Equipped with anode purge for contamination resistance 400° C maximum operating temperature Makeup gas types: argon (5%)/methane, nitrogen Radioactive source: 15 mCi 63Ni plated MDL: <0.04 pg/s lindane Dynamic range: > 104 with lindane

Weight
3

CLOSED

Sold
18  -  Gas Chromatograph
4.900 €

Manufacturer
PESTER PACK
Model
PEWO-PACK250
Year
2005
Observations
Min./ max format range of collation: - 60 x 30 x 60 mm / 360 x 180 x 250 mm Length: 1.100 - 1.900 mm Width: 1.050 mm Height: 1.750 mm Max. film width processed: 250 mm Max. format range: 180 x 400 x 200 mm Performance: 60 cycles /min (collations /min) Material: Polyethylene Control: Elau

Weight
225

CLOSED

Manufacturer
PESTER PACK
Model
PEWO-PACK250
Year
2005
Observations
Min./ max format range of collation: - 60 x 30 x 60 mm / 360 x 180 x 250 mm Length: 1.100 - 1.900 mm Width: 1.050 mm Height: 1.750 mm Max. film width processed: 250 mm Max. format range: 180 x 400 x 200 mm Performance: 60 cycles /min (collations /min) Material: Polyethylene Control: Elau

Weight
225

CLOSED

Sold
19  -  Cellophane machine
4.500 €

No. Series
Internal reference 350
Observations
Oil capsule machines bath

CLOSED

No. Series
Internal reference 350
Observations
Oil capsule machines bath

CLOSED

Sold
20  -  Oil capsule machines batch
4.500 €
Sold
21  -  oil capsule machines batch
4.250 €

Manufacturer
Fedegari
Model
FVA3/A1
Year
2005
Observations
Autoclave, Useful capacity: 140lt, chamber type: vertical with cylindrical creoss-section, chamber diameter: 500mm, useful height: 700mm, weight when empty: 175kg, weight when filled with water: 340kg, loading height: 875mm, external dimensions: WxHxD: 1200x1305x600mm, presión máx.: 3bar, 10.5A, 400V, 50Hz, 3ph.

Weight
6

CLOSED

Manufacturer
Fedegari
Model
FVA3/A1
Year
2005
Observations
Autoclave, Useful capacity: 140lt, chamber type: vertical with cylindrical creoss-section, chamber diameter: 500mm, useful height: 700mm, weight when empty: 175kg, weight when filled with water: 340kg, loading height: 875mm, external dimensions: WxHxD: 1200x1305x600mm, presión máx.: 3bar, 10.5A, 400V, 50Hz, 3ph.

Weight
6

CLOSED

Sold
22  -  Autoclave - automatic vertical sterilizer
3.500 €

Manufacturer
L.B. BOHLE
Model
K.A.120
Year
1995
Observations
Control Device For Dragees And Film-Coated Tablets,

Weight
273

CLOSED

Manufacturer
L.B. BOHLE
Model
K.A.120
Year
1995
Observations
Control Device For Dragees And Film-Coated Tablets,

Weight
273

CLOSED

Sold
23  -  sorting machine
3.000 €

Manufacturer
Thermo Scientific
Model
SOLAAR S Series AA - FS/GF95
Observations
The S Series of spectrometers offer no-compromise, single atomizer, multi-element AA systems, all in a footprint of less than 0.5 sq. m. A new Ebert optical system covers the range 185nm to 760nm as standard, with an optional wide range PMT up to 900nm, and sets new levels of performance. The standard 6 lamp auto-aligning turret (using data-coded or uncoded lamps, each with its own power supply) and Stockdale double beam system combine to produce excellent results. QuadLine deuterium background correction is standard on all units. Universal 50mm titanium burner supports all flame types and has high solids handling, excellent flame stability and low carbon build-up. Auto-optimising software control of burner height adjustment. Standard inert fluoroplastic spray chamber, with adjustable impact bead, and inert nebulizer provide unmatched sensitivity. Automatic binary flow gas management in the S4 model (or the semi-automatic version in the S2) guarantees reproducibility and safety. Feature-packed Windows 98/2000/XP-compatible SOLAAR software control offers multiple wizards to optimise system parameters and control analyses. Optional LCD Local Control available. Full range of optional accessories to provide an optimal solution to a wide range of analysis types, including flame autosamplers, graphite furnace and vapour analyses.

Weight
4

CLOSED

Manufacturer
Thermo Scientific
Model
SOLAAR S Series AA - FS/GF95
Observations
The S Series of spectrometers offer no-compromise, single atomizer, multi-element AA systems, all in a footprint of less than 0.5 sq. m. A new Ebert optical system covers the range 185nm to 760nm as standard, with an optional wide range PMT up to 900nm, and sets new levels of performance. The standard 6 lamp auto-aligning turret (using data-coded or uncoded lamps, each with its own power supply) and Stockdale double beam system combine to produce excellent results. QuadLine deuterium background correction is standard on all units. Universal 50mm titanium burner supports all flame types and has high solids handling, excellent flame stability and low carbon build-up. Auto-optimising software control of burner height adjustment. Standard inert fluoroplastic spray chamber, with adjustable impact bead, and inert nebulizer provide unmatched sensitivity. Automatic binary flow gas management in the S4 model (or the semi-automatic version in the S2) guarantees reproducibility and safety. Feature-packed Windows 98/2000/XP-compatible SOLAAR software control offers multiple wizards to optimise system parameters and control analyses. Optional LCD Local Control available. Full range of optional accessories to provide an optimal solution to a wide range of analysis types, including flame autosamplers, graphite furnace and vapour analyses.

Weight
4

CLOSED

Sold
24  -  Atomic absorption Spectrometer
2.900 €

Manufacturer
PERKIN ELMER
Model
OPTIMA 2000DV
No. Series
2072
Observations
The PerkinElmer OPTIMA 2000 optical emission spectrometer is a compact, bench-mounted, high-speed scanningCCD-based sequential ICP-OES system. All systems feature dual viewing of the plasma; a free-running 40-MHz solid-stateRF generator; a double monochromator; and a dual backside-illuminated charge-coupled device (DBI-CCD) detector. SPECTROMETER SPECIFICATIONS Double monochromator The OPTIMA 2000 ICP-OES uses a unique double-monochromator optical system.The first, or preselection monochromator, selects a small portion of the spectrum around the analytical line of interest.The second, the Echelle-based highdispersion monochromator, disperses the narrow wavelength range onto the DBI-CCD.This unique design results in a highspeed, high light-throughput optical system offering excellent resolution, all in a compact system.The entire system is shockmounted so that normal floor vibrations do not affect system performance.The sealed optical system can be purged with nitrogen for low UV (<190 nm) performance. Preselection monochromator The preselection monochromator has a focal length of 0.3 meter and uses a Stigmatic Littrow configuration. The disperser is a 30-degree CaF2 prism. Echelle monochromator The high-dispersion Echelle monochromator also has a focal length of 0.3 meter and a Stigmatic Littrow configuration.The Echelle grating used for dispersion has 79 lines/mm with a blaze angle of 63.8 degrees. Spectrometer parameters The spectral range is 160-900 nm. The slew rate is less than 3 seconds to cover the spectral range, and the measured resolution is <0.009 nm @ 200 nm.The prism and Echelle grating are rotated less than ± 2 degrees to accessany wavelength, dramatically improving analytical speed. Plasma viewing The dual-view optics of the OPTIMA 2000 ICP-OES allow the plasma to be viewed radially or axially. Dual viewing of the plasma provides the best possible combination, allowing for trace and major levels of an element to be determined without having to do extensive methods development at several alternate wavelengths.The OPTIMA 2000 software allows the selection of axial or radial viewing with automatic adjustment of the plasma viewing in both the vertical and horizontal direction. Detector The UV-sensitive, dual backside-illuminated CCD detector is cooled directly using a single-stage integrated Peltier cooler operated at approximately -8°C.The detector housing is hermetically sealed and is filled with dry nitrogen to eliminatecondensation.The detector has two photosensitive segments containing 176 by 128 pixels. One section is used for analytical measurements, and the other is a wavelength reference section.The solid-state detector collects both the analyte spectra and the nearby background spectra, allowing for simultaneous background correction and providing improved precision and analytical speed. Dynamic wavelength correction The wavelength reference section monitors a full wavelength neon spectrum, creating a dynamic wavelength scale used to actively correct wavelength positions.The resulting wavelength accuracy and reproducibility allows direct correction ‘on-peak’ measurements rather than time-consuming peak-search methods used in sequential ICP systems. ICP SYSTEM SPECIFICATIONS RF generator and coil The OPTIMA 2000 ICP-OES features a 40-MHz, free-running, solid-state (no power amplifier tube needed) RF generator, adjustable from 750 to 1500 watts, in 1-watt increments.The power efficiency is greater than 75% with <0.1% variation in output power stability.The solid-state components significantly increase reliability and can result in higher signal/power readings than conventional tube generators.The compact RF supply meets all FCC certification requirements for RF emission (Part 18 of FCC Rules and Regulations). It also complies with EC and VDE 0871 Class B requirements. Ignition and power control Plasma ignition is computer-controlled and totally automated. A unique software feature allows the plasma to be ignited automatically at a user-determined time to warm up the system prior to an analysis.The plasma can be turned off automatically after an analysis.True power control maintains the plasma power, even when changing sample matrices. Safety interlocks For user safety and system protection, the system constantly monitors water flow, shear gas pressure, argon pressure, sample compartment door closure and plasma stability, and displays the interlock status on the computer screen asgraphic symbols. If an interlock is interrupted, the plasma will automatically shut down safely. Cooling water A water recirculating cooling system is required, with approximately 4 L/min flow capacity at 310 to 550 kPa and atemperature between 15°C and 25°C.A NESLAB CFT 75D or equivalent is recommended. GAS FLOW CONTROLS Argon flow Computer-controlled solenoid valves are used to regulate the flow automatically within the range of 0-20 L/minin 1-L/min increments for plasma argon and 0 to 2.0 L/min in 0.1-L/min increments for auxiliary argon. A mass flow controller is supplied with all systems for the nebulizer argon flow and is variable between 0 and 2.0 L/min in 0.01-L/min increments. Shear gas A compressed air shear gas (18-25 L/min) is used to remove the plasma tail from the optical path, minimizing interferencesand extending the dynamic range.The shear gas design offers a maintenance-free and lower-cost (no use ofArgon) approach to removing the cooler plasma zone. SAMPLE INTRODUCTION SYSTEM Torch A unique, demountable torch design using one-piece quartz tubing for plasma and auxiliary gas flow is supplied.The standard torch includes a 2.0-mm i.d. alumina injector for full corrosion resistance to all acids, including hydrofluoric and aqua regia. A variety of other injectors are available. Torch mount The OPTIMA 2000 ICP-OES features a unique, externally mounted spray chamber. The mount can be adjusted (with theplasma on) for maximum performance in different matrices. Unlike other external spray chambers, which can drift with room temperature, the OPTIMA 2000 torch mount is enclosed in a thermally controlled area outside of the torch compartment. No tools are required for torch or sample introduction removal. Spray chamber The OPTIMA 2000 offers multiple sample introduction systems for complete flexibility.The standard Scott spray chamber is made from inert carbon-filled polyphenylene sulfide (PPS) for complete corrosion resistance to most acids, including HF. A glass cyclonic spray chamber is available and is typically used for high-performance trace elemental analyses. Nebulizer Both a cross-flow and a concentric nebulizer are available.The GemTip™ cross-flow nebulizer is manufactured from corrosion-resistant materials [sapphire/ruby tips in a polyetheretherketone (PEEK) body].The system can routinely handle 50% (v/v) solutions of HCl, HNO3, H2SO4, H3PO4, 20% (v/v) HF and 30% (w/v) NaOH. The system is fully compatible with other sample introduction devices such as ultrasonics, concentrics, and spark ablation. Peristaltic pump The three-channel, computer-controlled pump has variable speeds from 0.2 to 5 mL/min in 0.1-mL/min increments, using 0.76-mm (0.030 in.) i.d. tubing. Software features include FastPump™ and SmartRinse™, which dramatically improve the sample rinse-out and analysis times. Spares kit A spares kit, which includes an assortment of commonly required replacement items and consumables, is included withall Optima™ systems. PerkinElmer offers a complete range of accessories for the OPTIMA 2000. SYSTEM SPECIFICATIONS Power 200-240 VAC, 30A , single phase, 50/60 Hz (±1%) Dimensions 132 cm wide x 81 cm high x 76 cm deep Weight 125 kg Environmental The instrument will operate with a laboratory temperature between 15 and 35 °C (59 - 95 °F). For optimum instrumentperformance, the room temperature should be controlled at 20 ±2 °C

Weight
8

CLOSED

Manufacturer
PERKIN ELMER
Model
OPTIMA 2000DV
No. Series
2072
Observations
The PerkinElmer OPTIMA 2000 optical emission spectrometer is a compact, bench-mounted, high-speed scanningCCD-based sequential ICP-OES system. All systems feature dual viewing of the plasma; a free-running 40-MHz solid-stateRF generator; a double monochromator; and a dual backside-illuminated charge-coupled device (DBI-CCD) detector. SPECTROMETER SPECIFICATIONS Double monochromator The OPTIMA 2000 ICP-OES uses a unique double-monochromator optical system.The first, or preselection monochromator, selects a small portion of the spectrum around the analytical line of interest.The second, the Echelle-based highdispersion monochromator, disperses the narrow wavelength range onto the DBI-CCD.This unique design results in a highspeed, high light-throughput optical system offering excellent resolution, all in a compact system.The entire system is shockmounted so that normal floor vibrations do not affect system performance.The sealed optical system can be purged with nitrogen for low UV (<190 nm) performance. Preselection monochromator The preselection monochromator has a focal length of 0.3 meter and uses a Stigmatic Littrow configuration. The disperser is a 30-degree CaF2 prism. Echelle monochromator The high-dispersion Echelle monochromator also has a focal length of 0.3 meter and a Stigmatic Littrow configuration.The Echelle grating used for dispersion has 79 lines/mm with a blaze angle of 63.8 degrees. Spectrometer parameters The spectral range is 160-900 nm. The slew rate is less than 3 seconds to cover the spectral range, and the measured resolution is <0.009 nm @ 200 nm.The prism and Echelle grating are rotated less than ± 2 degrees to accessany wavelength, dramatically improving analytical speed. Plasma viewing The dual-view optics of the OPTIMA 2000 ICP-OES allow the plasma to be viewed radially or axially. Dual viewing of the plasma provides the best possible combination, allowing for trace and major levels of an element to be determined without having to do extensive methods development at several alternate wavelengths.The OPTIMA 2000 software allows the selection of axial or radial viewing with automatic adjustment of the plasma viewing in both the vertical and horizontal direction. Detector The UV-sensitive, dual backside-illuminated CCD detector is cooled directly using a single-stage integrated Peltier cooler operated at approximately -8°C.The detector housing is hermetically sealed and is filled with dry nitrogen to eliminatecondensation.The detector has two photosensitive segments containing 176 by 128 pixels. One section is used for analytical measurements, and the other is a wavelength reference section.The solid-state detector collects both the analyte spectra and the nearby background spectra, allowing for simultaneous background correction and providing improved precision and analytical speed. Dynamic wavelength correction The wavelength reference section monitors a full wavelength neon spectrum, creating a dynamic wavelength scale used to actively correct wavelength positions.The resulting wavelength accuracy and reproducibility allows direct correction ‘on-peak’ measurements rather than time-consuming peak-search methods used in sequential ICP systems. ICP SYSTEM SPECIFICATIONS RF generator and coil The OPTIMA 2000 ICP-OES features a 40-MHz, free-running, solid-state (no power amplifier tube needed) RF generator, adjustable from 750 to 1500 watts, in 1-watt increments.The power efficiency is greater than 75% with <0.1% variation in output power stability.The solid-state components significantly increase reliability and can result in higher signal/power readings than conventional tube generators.The compact RF supply meets all FCC certification requirements for RF emission (Part 18 of FCC Rules and Regulations). It also complies with EC and VDE 0871 Class B requirements. Ignition and power control Plasma ignition is computer-controlled and totally automated. A unique software feature allows the plasma to be ignited automatically at a user-determined time to warm up the system prior to an analysis.The plasma can be turned off automatically after an analysis.True power control maintains the plasma power, even when changing sample matrices. Safety interlocks For user safety and system protection, the system constantly monitors water flow, shear gas pressure, argon pressure, sample compartment door closure and plasma stability, and displays the interlock status on the computer screen asgraphic symbols. If an interlock is interrupted, the plasma will automatically shut down safely. Cooling water A water recirculating cooling system is required, with approximately 4 L/min flow capacity at 310 to 550 kPa and atemperature between 15°C and 25°C.A NESLAB CFT 75D or equivalent is recommended. GAS FLOW CONTROLS Argon flow Computer-controlled solenoid valves are used to regulate the flow automatically within the range of 0-20 L/minin 1-L/min increments for plasma argon and 0 to 2.0 L/min in 0.1-L/min increments for auxiliary argon. A mass flow controller is supplied with all systems for the nebulizer argon flow and is variable between 0 and 2.0 L/min in 0.01-L/min increments. Shear gas A compressed air shear gas (18-25 L/min) is used to remove the plasma tail from the optical path, minimizing interferencesand extending the dynamic range.The shear gas design offers a maintenance-free and lower-cost (no use ofArgon) approach to removing the cooler plasma zone. SAMPLE INTRODUCTION SYSTEM Torch A unique, demountable torch design using one-piece quartz tubing for plasma and auxiliary gas flow is supplied.The standard torch includes a 2.0-mm i.d. alumina injector for full corrosion resistance to all acids, including hydrofluoric and aqua regia. A variety of other injectors are available. Torch mount The OPTIMA 2000 ICP-OES features a unique, externally mounted spray chamber. The mount can be adjusted (with theplasma on) for maximum performance in different matrices. Unlike other external spray chambers, which can drift with room temperature, the OPTIMA 2000 torch mount is enclosed in a thermally controlled area outside of the torch compartment. No tools are required for torch or sample introduction removal. Spray chamber The OPTIMA 2000 offers multiple sample introduction systems for complete flexibility.The standard Scott spray chamber is made from inert carbon-filled polyphenylene sulfide (PPS) for complete corrosion resistance to most acids, including HF. A glass cyclonic spray chamber is available and is typically used for high-performance trace elemental analyses. Nebulizer Both a cross-flow and a concentric nebulizer are available.The GemTip™ cross-flow nebulizer is manufactured from corrosion-resistant materials [sapphire/ruby tips in a polyetheretherketone (PEEK) body].The system can routinely handle 50% (v/v) solutions of HCl, HNO3, H2SO4, H3PO4, 20% (v/v) HF and 30% (w/v) NaOH. The system is fully compatible with other sample introduction devices such as ultrasonics, concentrics, and spark ablation. Peristaltic pump The three-channel, computer-controlled pump has variable speeds from 0.2 to 5 mL/min in 0.1-mL/min increments, using 0.76-mm (0.030 in.) i.d. tubing. Software features include FastPump™ and SmartRinse™, which dramatically improve the sample rinse-out and analysis times. Spares kit A spares kit, which includes an assortment of commonly required replacement items and consumables, is included withall Optima™ systems. PerkinElmer offers a complete range of accessories for the OPTIMA 2000. SYSTEM SPECIFICATIONS Power 200-240 VAC, 30A , single phase, 50/60 Hz (±1%) Dimensions 132 cm wide x 81 cm high x 76 cm deep Weight 125 kg Environmental The instrument will operate with a laboratory temperature between 15 and 35 °C (59 - 95 °F). For optimum instrumentperformance, the room temperature should be controlled at 20 ±2 °C

Weight
8

CLOSED

Sold
25  -  Optical emission spectrometer
2.500 €

Manufacturer
PHARMA TECHNOLOGIC - LOCK
Model
MET 30+
No. Series
17498
Observations
The metal detector can detect and reject microscopic contaminants in pharmaceutical production lines, such as tiny lengths of sieve mesh and press tooling fragments, at speeds of up to 30,000 tablets per minute.

Weight
215

CLOSED

Manufacturer
PHARMA TECHNOLOGIC - LOCK
Model
MET 30+
No. Series
17498
Observations
The metal detector can detect and reject microscopic contaminants in pharmaceutical production lines, such as tiny lengths of sieve mesh and press tooling fragments, at speeds of up to 30,000 tablets per minute.

Weight
215

CLOSED

Sold
26  -  Tablet debuster lock and metal detector
2.500 €

Manufacturer
IPROCOMSA
Model
500LT
Observations
Capacity tanks: 500Lts

Weight
283

CLOSED

Manufacturer
IPROCOMSA
Model
500LT
Observations
Capacity tanks: 500Lts

Weight
283

CLOSED

Sold
27  -  Liquid mixer tank
2.000 €

Manufacturer
METTLET TOLEDO
Model
IND890
Observations
Thanks to its standard touch screen, the IND890 is easy and reliable to operate even in the harshest environments, with IP69k protection. The application terminal also sets new standards in extremely complex weighing processes. It provides the perfect connection between a PC and a scale and the company network. With Windows operating system it can be used as a PC for aggressive areas having the optional ability to interface with scales or weighing system.

Weight
341

CLOSED

Manufacturer
METTLET TOLEDO
Model
IND890
Observations
Thanks to its standard touch screen, the IND890 is easy and reliable to operate even in the harshest environments, with IP69k protection. The application terminal also sets new standards in extremely complex weighing processes. It provides the perfect connection between a PC and a scale and the company network. With Windows operating system it can be used as a PC for aggressive areas having the optional ability to interface with scales or weighing system.

Weight
341

CLOSED

Sold
28  -  Weighing terminal
2.000 €

Manufacturer
Varian
Model
CP3800
Observations
The Gas Chromatograph meets all your analytical requirements with practical solutions for simple and complex applications. In a standard configuration, the CP-3800 accommodates up to three injectors and three detectors, all operating simultaneously. In addition, the CP-3800 is easily configured to perform on-line analyses for monitoring critical gas and liquid process streams. The CP-3800’s flexible platform lets you start with a basic configuration and add a wide variety of options in the field. Options include additional channels, gas and liquid sampling valves, and external sampling devices.

Weight
5

CLOSED

Manufacturer
Varian
Model
CP3800
Observations
The Gas Chromatograph meets all your analytical requirements with practical solutions for simple and complex applications. In a standard configuration, the CP-3800 accommodates up to three injectors and three detectors, all operating simultaneously. In addition, the CP-3800 is easily configured to perform on-line analyses for monitoring critical gas and liquid process streams. The CP-3800’s flexible platform lets you start with a basic configuration and add a wide variety of options in the field. Options include additional channels, gas and liquid sampling valves, and external sampling devices.

Weight
5

CLOSED

Sold
29  -  Gas Chromatograph
1.500 €

Manufacturer
SYSTEC
Model
DX-45
Observations
Dimensions of useful capacity Ø x depth in mm 344 x 500, Volume of useful capacity in total / nominal liters 50/45. External dimensions in mm Height 585. Width 620. Depth 755. Net weight (kg) 105. Heating power kW 3,5.

Weight
46

CLOSED

Manufacturer
SYSTEC
Model
DX-45
Observations
Dimensions of useful capacity Ø x depth in mm 344 x 500, Volume of useful capacity in total / nominal liters 50/45. External dimensions in mm Height 585. Width 620. Depth 755. Net weight (kg) 105. Heating power kW 3,5.

Weight
46

CLOSED

Sold
30  -  Autoclave
1.500 €

Manufacturer
I.RAND-MASTERIA
Model
UP5-15-75/Masteria
Year
2005
No. Series
2191315
Observations
Power: 15kW. 7,5bar. 1470rev/min. With Tank 500Lt, and dryer Masteria.

Weight
241

CLOSED

Manufacturer
I.RAND-MASTERIA
Model
UP5-15-75/Masteria
Year
2005
No. Series
2191315
Observations
Power: 15kW. 7,5bar. 1470rev/min. With Tank 500Lt, and dryer Masteria.

Weight
241

CLOSED

Sold
31  -  Compressed air installation: air compressor, dryer and prevo
1.500 €