No. of sale: 300621L
Starting dateManufacturerSTERIS ModelVHP100P-VHP100R Weight286
ManufacturerSTERIS ModelVHP100P-VHP100R Weight286
CLOSED
ManufacturerLOCK INSPECT. SYSTEM ModelMET 30+ ObservationsThe MET 30+ detector uses the latest developments in digital signal processingensuring complete product integrity. The detector is able to store up to 100 sets ofautomatic product set up values in memory.The MET 30+ detector is capable of detecting and rejecting ferrous, non-ferrous andnon-magnetic stainless steel. Weight301
ManufacturerLOCK INSPECT. SYSTEM ModelMET 30+ ObservationsThe MET 30+ detector uses the latest developments in digital signal processingensuring complete product integrity. The detector is able to store up to 100 sets ofautomatic product set up values in memory.The MET 30+ detector is capable of detecting and rejecting ferrous, non-ferrous andnon-magnetic stainless steel. Weight301
CLOSED
ManufacturerSOCO SYSTEM ModelF-100.5 ObservationsMedidas de caja: Max. L x W x H: Infinito x 520 x 505mm. Min. L x W x H 160 x 90 x 90/130mm. Capacidad Max.: 30/ min. Equipamiento elétrico 3 x 230/400 V, 50-60 Hz o 3 x 415/460 V, 50-60 Hz. Consumo 0,3 kW. Diametro de bobina máx. 370 mm. Weight345
ManufacturerSOCO SYSTEM ModelF-100.5 ObservationsMedidas de caja: Max. L x W x H: Infinito x 520 x 505mm. Min. L x W x H 160 x 90 x 90/130mm. Capacidad Max.: 30/ min. Equipamiento elétrico 3 x 230/400 V, 50-60 Hz o 3 x 415/460 V, 50-60 Hz. Consumo 0,3 kW. Diametro de bobina máx. 370 mm. Weight345
CLOSED
ManufacturerTHERMO EUROGLAS ModelELS 3000 No. Series3417 ObservationsThe Thermo Electron ELS 3000 auto-sampler is designed for fully automated introduction of light hydrocarbon samples. The sampler has 74 positions for 2 ml screw capped sample vials and can inject a maximum of 250 µl. Key advantages of the ELS 3000 autosampler are: • Designed for a 24 hours operational environment • All operations fully controlled by Windows® (ThEuS) software • Easy connection to universal syringe type liquids or boat introduction modules • Wash solvent and waste containers included. Weight30
ManufacturerTHERMO EUROGLAS ModelELS 3000 No. Series3417 ObservationsThe Thermo Electron ELS 3000 auto-sampler is designed for fully automated introduction of light hydrocarbon samples. The sampler has 74 positions for 2 ml screw capped sample vials and can inject a maximum of 250 µl. Key advantages of the ELS 3000 autosampler are: • Designed for a 24 hours operational environment • All operations fully controlled by Windows® (ThEuS) software • Easy connection to universal syringe type liquids or boat introduction modules • Wash solvent and waste containers included. Weight30
CLOSED
ManufacturerERLAB GROUP ModelCAPTAIR FLEX M321 Year2012 ObservationsDuctless filtering fume hoods and vented storage cabinetsNumber of filtration columns 1 Number of fans (IP44) 1 Air flow rate 230 m3/h Air velocity at openings (in on-position) 0,4 to 0,6 m/s Voltage/frequency 90 - 264 V / 50 Hz Structure Anti-corrosion steel coated with acid-proof Panels 8 mm synthetic glass Filtration module Polypropylene. Dimensions: Interior: 764x540x860mm Exterior 800x620x1120mm. Weight72
ManufacturerERLAB GROUP ModelCAPTAIR FLEX M321 Year2012 ObservationsDuctless filtering fume hoods and vented storage cabinetsNumber of filtration columns 1 Number of fans (IP44) 1 Air flow rate 230 m3/h Air velocity at openings (in on-position) 0,4 to 0,6 m/s Voltage/frequency 90 - 264 V / 50 Hz Structure Anti-corrosion steel coated with acid-proof Panels 8 mm synthetic glass Filtration module Polypropylene. Dimensions: Interior: 764x540x860mm Exterior 800x620x1120mm. Weight72
CLOSED
ManufacturerMETALCHEK ObservationsTECHNICAL DATA Electric frequency Hz 50 Voltage Volt 230 Max throughput Tablets/min 30.000 Detects ferrous contaminant up to mm 0.25 Non ferrous up to mm 0.3 Stainless steel up to mm 0.4 Dimensions mm 900 x 800 x 1630 Weight Kg 50 Weight148
ManufacturerMETALCHEK ObservationsTECHNICAL DATA Electric frequency Hz 50 Voltage Volt 230 Max throughput Tablets/min 30.000 Detects ferrous contaminant up to mm 0.25 Non ferrous up to mm 0.3 Stainless steel up to mm 0.4 Dimensions mm 900 x 800 x 1630 Weight Kg 50 Weight148
CLOSED
ManufacturerLOMA SYSTEMS ModelMICRO PH 2 Year1996 No. Series52829 ObservationsPH Pharmaceutical Metal Detector is designed for inspecting tablets and capsules after the tablet and de-duster process with throughput of up to 30,000 units per minute. Weight300
ManufacturerLOMA SYSTEMS ModelMICRO PH 2 Year1996 No. Series52829 ObservationsPH Pharmaceutical Metal Detector is designed for inspecting tablets and capsules after the tablet and de-duster process with throughput of up to 30,000 units per minute. Weight300
CLOSED
ManufacturerPHASE TECHNOLOGY ModelCPA-70V No. Series700010485 Weight28
ManufacturerPHASE TECHNOLOGY ModelCPA-70V No. Series700010485 Weight28
CLOSED
ManufacturerMETROHM Model716 DMS TITRINO ObservationsSpecifications: - Voltage: 0 to 2000mV - Current: 0 to 200µA - Temperature: -150 to 450°C - Dimensions (W x H x D): 15 x 45 x 27.5 cm - Weight: 3.4 kg Weight33
ManufacturerMETROHM Model716 DMS TITRINO ObservationsSpecifications: - Voltage: 0 to 2000mV - Current: 0 to 200µA - Temperature: -150 to 450°C - Dimensions (W x H x D): 15 x 45 x 27.5 cm - Weight: 3.4 kg Weight33
CLOSED
ManufacturerMETROHM Model716DMS TRITINO No. Series11140455 ObservationsSpecifications: - Voltage: 220/230/240V - Current: 0 to 200µA - Temperature: -150 to 450°C - Dimensions (W x H x D): 15 x 45 x 27.5 cm - Weight: 3.4 kg Weight35
ManufacturerMETROHM Model716DMS TRITINO No. Series11140455 ObservationsSpecifications: - Voltage: 220/230/240V - Current: 0 to 200µA - Temperature: -150 to 450°C - Dimensions (W x H x D): 15 x 45 x 27.5 cm - Weight: 3.4 kg Weight35
CLOSED
ManufacturerDIONEX ModelP580A LPG No. Series9931257 ObservationsThe Dionex P580 Pump is a high precision pump for the HPLC analysis. The patented isokinetic pre-compression allows a precise and zero-pulsation flow. With flow rates ranging from 1μl/min to 10ml/min (analytical version) and operating pressures up to 50.0 MPa (500 bar), the P580 is suitable for both regular and micro HPLC. Specifications: - Power requirements: 100V / 230V ±10%, 50/60Hz - Low-pressure gradient: quaternary - High-pressure gradient: binary (with optional "Solvent Selector": from 4 solvents). Flow gradient can be combined with solvent gradient - Standard mixing chamber volume: 0.2 ml Weight53
ManufacturerDIONEX ModelP580A LPG No. Series9931257 ObservationsThe Dionex P580 Pump is a high precision pump for the HPLC analysis. The patented isokinetic pre-compression allows a precise and zero-pulsation flow. With flow rates ranging from 1μl/min to 10ml/min (analytical version) and operating pressures up to 50.0 MPa (500 bar), the P580 is suitable for both regular and micro HPLC. Specifications: - Power requirements: 100V / 230V ±10%, 50/60Hz - Low-pressure gradient: quaternary - High-pressure gradient: binary (with optional "Solvent Selector": from 4 solvents). Flow gradient can be combined with solvent gradient - Standard mixing chamber volume: 0.2 ml Weight53
CLOSED
ManufacturerDIONEX ModelRF2000 ObservationsDionex Fluorescence Detector RF-2000 enhances productivity of analysis through its highest performance and stability. It supports operation via data system Chromeleon. Specifications: Light source: 150W xenon lamp Light source chamber: Ozone self dissolving type lamp house Monochromators: Ion brazed holographic concave diffraction grating monochromators F/2. 4 for both excitation and emission sides Number of grooves: 900 lines/mm Wavelength range: 200~650nm and 0 order Bandwidth: 15nm for both excitation and emission sides Wavelength accuracy: ±2nm Wavelength repeatability: ±0.2nm Wavelength scanning speed: SUPER, FAST, MEDIUM and SLOW, 4 steps SUPER: Approx. 3,000nm/min FAST: Approx. 600nm/min MEDIUM: Approx. 120nm/min SLOW: Approx. 24nm/min Wavelength moving speed: Approx. 15,000nm/min Detector: Signal side: Photomultiplier tube Monitor side: Photodiode Measuring method: Ratio compensation system with monochromatic light monitoring. Time constant: 0.1, 0.5, 1.5and 3s, 4 steps. Sensitivity: HIGH, MED and LOW, 3 steps (sensitivity difference is approx. 32 times) Gain: x1, x4, and x16, 3 steps (approx. 1 time, 4 times, and 16 times) Range: 1/∞ (0mV), x1, x1/2, x1/4, x1/8, x1/16, x1/32, x1/64, x1/128, x1/256 Output terminals: Recorder: 1mV, 10mV Integrator: 1V/FS Contact signal output (EVENT OUT output) Input terminals: Contact signal input (START input, STOP input) Cell: 12µl square quarts flow cell, pressure tolerance 1.96Mpa {20kgf/cm2 } (figure inside { } is reference.) Communication: Controllable by CHROMELEON via RS-232C Display unit: Fluorescent display tube Measuring function: * Monitor function Auto zero, Base line shift * Time program function Up to 32 steps can be programmed. * Wavelength scanning function Excitation and Emission wavelength scanning Differential spectrum Plot output Weight63
ManufacturerDIONEX ModelRF2000 ObservationsDionex Fluorescence Detector RF-2000 enhances productivity of analysis through its highest performance and stability. It supports operation via data system Chromeleon. Specifications: Light source: 150W xenon lamp Light source chamber: Ozone self dissolving type lamp house Monochromators: Ion brazed holographic concave diffraction grating monochromators F/2. 4 for both excitation and emission sides Number of grooves: 900 lines/mm Wavelength range: 200~650nm and 0 order Bandwidth: 15nm for both excitation and emission sides Wavelength accuracy: ±2nm Wavelength repeatability: ±0.2nm Wavelength scanning speed: SUPER, FAST, MEDIUM and SLOW, 4 steps SUPER: Approx. 3,000nm/min FAST: Approx. 600nm/min MEDIUM: Approx. 120nm/min SLOW: Approx. 24nm/min Wavelength moving speed: Approx. 15,000nm/min Detector: Signal side: Photomultiplier tube Monitor side: Photodiode Measuring method: Ratio compensation system with monochromatic light monitoring. Time constant: 0.1, 0.5, 1.5and 3s, 4 steps. Sensitivity: HIGH, MED and LOW, 3 steps (sensitivity difference is approx. 32 times) Gain: x1, x4, and x16, 3 steps (approx. 1 time, 4 times, and 16 times) Range: 1/∞ (0mV), x1, x1/2, x1/4, x1/8, x1/16, x1/32, x1/64, x1/128, x1/256 Output terminals: Recorder: 1mV, 10mV Integrator: 1V/FS Contact signal output (EVENT OUT output) Input terminals: Contact signal input (START input, STOP input) Cell: 12µl square quarts flow cell, pressure tolerance 1.96Mpa {20kgf/cm2 } (figure inside { } is reference.) Communication: Controllable by CHROMELEON via RS-232C Display unit: Fluorescent display tube Measuring function: * Monitor function Auto zero, Base line shift * Time program function Up to 32 steps can be programmed. * Wavelength scanning function Excitation and Emission wavelength scanning Differential spectrum Plot output Weight63
CLOSED