No. of sale: 300621L
Starting dateManufacturerBELCA ModelBLSB-50 Year2006 Observationsmax. product length: 450 mm - max product width: 450 mm - max product height: 150 mm - possible packaging materials: polyethylene, polypropylene, polyolefins and PVC - max. diameter of the foil: 300 mm - max film width: 600 mm - max production speed: 20 m / min - number of cycles: 30 - 41 / minute. power: 2.5 kW. 380 V / 50 Hz Weight280
ManufacturerBELCA ModelBLSB-50 Year2006 Observationsmax. product length: 450 mm - max product width: 450 mm - max product height: 150 mm - possible packaging materials: polyethylene, polypropylene, polyolefins and PVC - max. diameter of the foil: 300 mm - max film width: 600 mm - max production speed: 20 m / min - number of cycles: 30 - 41 / minute. power: 2.5 kW. 380 V / 50 Hz Weight280
CLOSED
ManufacturerANRITSU ModelKW9001AP ObservationsThe KW9001AP can measure up to 2.000 capsules/min.; with each capsule individually checkweighed into three classifications (overweight, proper weight or lightweight) every minute. With a weighing range between 20 and 1.000 mg, maximum accuracy of ±2 mg at 3s and a maximum speed of 120.000 capsules/hour, the KW9001AP accepts and rejects capsules quickly and efficiently. Weight354
ManufacturerANRITSU ModelKW9001AP ObservationsThe KW9001AP can measure up to 2.000 capsules/min.; with each capsule individually checkweighed into three classifications (overweight, proper weight or lightweight) every minute. With a weighing range between 20 and 1.000 mg, maximum accuracy of ±2 mg at 3s and a maximum speed of 120.000 capsules/hour, the KW9001AP accepts and rejects capsules quickly and efficiently. Weight354
CLOSED
ManufacturerBWB TECHNOLOGIES UK ModelXP No. Series20090074 ObservationsSample rate 2 - 3.5ml/min Tubing materials Silicone and Tygon Required desk space for Instrument 50cm (H) x 45cm (W) x 45cm (D) For Safety reasons the Flame photometer requires 1m of unobstructed space above to allow dissipation of heat from the chimney. Instrument size XP Flame Photometer 51cm (H) x 39cm (W) x 35cm (D) Shipping 65cm (H) x 49cm (W) x 43cm (D) Weight XP Flame Photometer - 20kg Optimal range Single point calibration Na 0.1 - 60ppm K 0.05 - 100ppm Li 0.05 - 50ppm Ca 1.0 - 100ppm Ba 1.6 - 100ppm Multi Point Calibration Na 0.1 - 1000ppm K 0.05 - 1000ppm Li 0.05 - 1000ppm Ca 1.0 - 1000ppm Ba 5.0 - 3000ppm Reproducibility <1% Coefficient of variability for 20 consecutive samples over ten minutes at concentrations of 100ppm or less. (After instrument stabilisation). Specificity Na/K/Li = <1% to each other when equal in concentration at <100ppm Limit of detection (LOD) and limit of quantification (LOQ) LOD LOQ Na - 0.03ppm Na - 0.1ppm K - 0.02ppm K - 0.05ppm Li - 0.02ppm Li - 0.05ppm Ca - 0.3ppm Ca - 1ppm Ba - 1.6ppm Ba - 5.0ppm Time to stability Less than 15 seconds after sample is introduced into the flame. Ions measured Simultaneous measurement of Na, K, Li, Ca, Ba Interfaces USB 0-2.5 volt output (based on sample concentration linked to element of users choice) Optional 4-20mA output in place of the above Optional integrated printer .csv and .pdf generated reports and files via FP-PC software Recommended minimum warm up time based on ambient temperature 21ºC - 25 minutes Power requirements 100V - 250V AC at 50 or 60Hz automatically selecting Fuel requirement Propane, Butane or Natural Gas* regulated to 19Bar. Flow rate of 0.4l/min Readout LCD, four line, alpha numeric, back lit. Weight15
ManufacturerBWB TECHNOLOGIES UK ModelXP No. Series20090074 ObservationsSample rate 2 - 3.5ml/min Tubing materials Silicone and Tygon Required desk space for Instrument 50cm (H) x 45cm (W) x 45cm (D) For Safety reasons the Flame photometer requires 1m of unobstructed space above to allow dissipation of heat from the chimney. Instrument size XP Flame Photometer 51cm (H) x 39cm (W) x 35cm (D) Shipping 65cm (H) x 49cm (W) x 43cm (D) Weight XP Flame Photometer - 20kg Optimal range Single point calibration Na 0.1 - 60ppm K 0.05 - 100ppm Li 0.05 - 50ppm Ca 1.0 - 100ppm Ba 1.6 - 100ppm Multi Point Calibration Na 0.1 - 1000ppm K 0.05 - 1000ppm Li 0.05 - 1000ppm Ca 1.0 - 1000ppm Ba 5.0 - 3000ppm Reproducibility <1% Coefficient of variability for 20 consecutive samples over ten minutes at concentrations of 100ppm or less. (After instrument stabilisation). Specificity Na/K/Li = <1% to each other when equal in concentration at <100ppm Limit of detection (LOD) and limit of quantification (LOQ) LOD LOQ Na - 0.03ppm Na - 0.1ppm K - 0.02ppm K - 0.05ppm Li - 0.02ppm Li - 0.05ppm Ca - 0.3ppm Ca - 1ppm Ba - 1.6ppm Ba - 5.0ppm Time to stability Less than 15 seconds after sample is introduced into the flame. Ions measured Simultaneous measurement of Na, K, Li, Ca, Ba Interfaces USB 0-2.5 volt output (based on sample concentration linked to element of users choice) Optional 4-20mA output in place of the above Optional integrated printer .csv and .pdf generated reports and files via FP-PC software Recommended minimum warm up time based on ambient temperature 21ºC - 25 minutes Power requirements 100V - 250V AC at 50 or 60Hz automatically selecting Fuel requirement Propane, Butane or Natural Gas* regulated to 19Bar. Flow rate of 0.4l/min Readout LCD, four line, alpha numeric, back lit. Weight15
CLOSED
ManufacturerCARL KURT WALTHER ModelLB100 Year1995 ObservationsTank Capacity : 100Lts Weight191
ManufacturerCARL KURT WALTHER ModelLB100 Year1995 ObservationsTank Capacity : 100Lts Weight191
CLOSED
ManufacturerMACHINES COLLETTE ModelMP-20 ObservationsMixer capaciry: 20Lts Weight192
ManufacturerMACHINES COLLETTE ModelMP-20 ObservationsMixer capaciry: 20Lts Weight192
CLOSED
ManufacturerSOCIETE FRANÇAISE D'ETIQUETAGE Year1994 No. Series1452 Weight216
ManufacturerSOCIETE FRANÇAISE D'ETIQUETAGE Year1994 No. Series1452 Weight216
CLOSED
ManufacturerGARDNER DENVER ModelVTR100 Year2010 ObservationsDry running rotary vane pump. Volume flow 100 to 120 m³/hr. Ultimate vacuum 150 mbar. 3-3,6Kw. 1.450-1.740 rev/min. Weight269
ManufacturerGARDNER DENVER ModelVTR100 Year2010 ObservationsDry running rotary vane pump. Volume flow 100 to 120 m³/hr. Ultimate vacuum 150 mbar. 3-3,6Kw. 1.450-1.740 rev/min. Weight269
CLOSED
ManufacturerBECKER ModelU 4.165 F/K Year2007 ObservationsVolume flow 160 to 192 m³/hr. Ultimate vacuum 0.5 mbar. 4-4.8Kw. 1.420-1.700 rev/min. Weight271
ManufacturerBECKER ModelU 4.165 F/K Year2007 ObservationsVolume flow 160 to 192 m³/hr. Ultimate vacuum 0.5 mbar. 4-4.8Kw. 1.420-1.700 rev/min. Weight271
CLOSED
ManufacturerSEPHA ObservationsOperating Speed: Up to 50 packs per minute Construction: Stainless Steel (Grade 316 & 304) Tooling Changeover: 5 minutes Utilities: Electrical: 110/230V Single Phase AC 50/60 Hz / Air: Min. 450L/min at 0.6Mpa [ISO8573-1:2010 CLASS 2] Machine Dimensions: 965mm (L) 665mm (W) 1540mm (H) Machine Weight: 230kg. Blister Type Push-through, Child resistant, Peelable & Multi-product Pack Dimensions: Width: Min. 82mm Max. 105mm / Length: Min. 33mm Max. 140mm Weight307
ManufacturerSEPHA ObservationsOperating Speed: Up to 50 packs per minute Construction: Stainless Steel (Grade 316 & 304) Tooling Changeover: 5 minutes Utilities: Electrical: 110/230V Single Phase AC 50/60 Hz / Air: Min. 450L/min at 0.6Mpa [ISO8573-1:2010 CLASS 2] Machine Dimensions: 965mm (L) 665mm (W) 1540mm (H) Machine Weight: 230kg. Blister Type Push-through, Child resistant, Peelable & Multi-product Pack Dimensions: Width: Min. 82mm Max. 105mm / Length: Min. 33mm Max. 140mm Weight307
CLOSED
ManufacturerTECHNILAB ModelVTD150MD Year2010 ObservationsThe equipment can dedust up to 500,000 tablets per hour. Equipped with a metal particles detector. Weight316
ManufacturerTECHNILAB ModelVTD150MD Year2010 ObservationsThe equipment can dedust up to 500,000 tablets per hour. Equipped with a metal particles detector. Weight316
CLOSED
ManufacturerROSAND ModelRH2000 ObservationsMaximum force: 12kN (standard) Frame stiffness:100kN. Maximum speed:600mm/min (standard). 1200mm/min (high speed option) Dynamic range in speed:>120,000:1. (240,000:1 with high speed option)Speed uncertainty: <0.1%Temperature range: Ambient to 400°C (standard). Ambient to 500°C (high temperature option). 5°C to 200°C (low temperature cooling coil option)Temperature control range: Weight333
ManufacturerROSAND ModelRH2000 ObservationsMaximum force: 12kN (standard) Frame stiffness:100kN. Maximum speed:600mm/min (standard). 1200mm/min (high speed option) Dynamic range in speed:>120,000:1. (240,000:1 with high speed option)Speed uncertainty: <0.1%Temperature range: Ambient to 400°C (standard). Ambient to 500°C (high temperature option). 5°C to 200°C (low temperature cooling coil option)Temperature control range: Weight333
CLOSED
ManufacturerANRITSU ModelK525D CHECKWEIGHER ObservationsCapsule checkweigher. 10 lane, set up for 0 capsules, 110 volt with panel. Weight337
ManufacturerANRITSU ModelK525D CHECKWEIGHER ObservationsCapsule checkweigher. 10 lane, set up for 0 capsules, 110 volt with panel. Weight337
CLOSED
ManufacturerANRITSU ModelK525D CHECKWEIGHER ObservationsCapsule checkweigher. 10 lane, set up for 0 capsules, 110 volt with panel. Weight338
ManufacturerANRITSU ModelK525D CHECKWEIGHER ObservationsCapsule checkweigher. 10 lane, set up for 0 capsules, 110 volt with panel. Weight338
CLOSED
ManufacturerCREMER ModelCTU1220 Year2014 No. Series24597001 ObservationsNúmero de canales de conteo 12; Max. velocidad de conteo 5.500 productos / min. Max. salida 55; Altura de la botella 40-200 mm; Diámetro de la botella 20-110 mm Weight356
ManufacturerCREMER ModelCTU1220 Year2014 No. Series24597001 ObservationsNúmero de canales de conteo 12; Max. velocidad de conteo 5.500 productos / min. Max. salida 55; Altura de la botella 40-200 mm; Diámetro de la botella 20-110 mm Weight356
CLOSED
ManufacturerTHERMO SCIENTIFIC ModelMSC 1.2 No. Series40990208 ObservationsSpecifications: Exterior dimensions: Depth: 80cm. Height: 152cm. Width: 130cm Certifications/Compliance: EN 12469, by TüV Nord, LNE (0.9 and 1.2m). EN 12469, by TüV Nord (1.5 and 1.8m) Energy Consumption (Reduced Flow Mode): <40w Height (Metric): 152 cm (Exterior) Ports: TUV-Approved Type: Biological Safety Cabinet Width (Metric) Interior: 1.2m Exhaust Air Filter: HEPA H 14 EN 1822, 99.995% at 0.3µm particle Voltage: 230V Energy Consumption (Operating Set Point): 200w Noise Level: <59dBA Receptacles: One double, right side Weight289
ManufacturerTHERMO SCIENTIFIC ModelMSC 1.2 No. Series40990208 ObservationsSpecifications: Exterior dimensions: Depth: 80cm. Height: 152cm. Width: 130cm Certifications/Compliance: EN 12469, by TüV Nord, LNE (0.9 and 1.2m). EN 12469, by TüV Nord (1.5 and 1.8m) Energy Consumption (Reduced Flow Mode): <40w Height (Metric): 152 cm (Exterior) Ports: TUV-Approved Type: Biological Safety Cabinet Width (Metric) Interior: 1.2m Exhaust Air Filter: HEPA H 14 EN 1822, 99.995% at 0.3µm particle Voltage: 230V Energy Consumption (Operating Set Point): 200w Noise Level: <59dBA Receptacles: One double, right side Weight289
CLOSED