Gutinvest

Lots

Pharma and laboratory equipment

No. of sale: 300621L

Starting date
25/05/2021 14:00:00
Closing Date
30/06/2021 14:00:00
Viewing days
by appointment
Location
Gerona - Spain
Online auction of more than 350 lots, belonging to the pharmaceutical and biotechnology sector. We highlight tablet counters, encapsulators, packaging machines, cartoning machines, autoclaves, gas chromatographs, metal detectors, laminar flow cabinets, pipettes ...
Sales commission
18% buyers premium
Payment methods

Manufacturer
BELCA
Model
BLSB-50
Year
2006
Observations
max. product length: 450 mm - max product width: 450 mm - max product height: 150 mm - possible packaging materials: polyethylene, polypropylene, polyolefins and PVC - max. diameter of the foil: 300 mm - max film width: 600 mm - max production speed: 20 m / min - number of cycles: 30 - 41 / minute. power: 2.5 kW. 380 V / 50 Hz

Weight
280

CLOSED

Manufacturer
BELCA
Model
BLSB-50
Year
2006
Observations
max. product length: 450 mm - max product width: 450 mm - max product height: 150 mm - possible packaging materials: polyethylene, polypropylene, polyolefins and PVC - max. diameter of the foil: 300 mm - max film width: 600 mm - max production speed: 20 m / min - number of cycles: 30 - 41 / minute. power: 2.5 kW. 380 V / 50 Hz

Weight
280

CLOSED

Sold
32  -  Automatic shrink wrapping machine
1.500 €

Manufacturer
ANRITSU
Model
KW9001AP
Observations
The KW9001AP can measure up to 2.000 capsules/min.; with each capsule individually checkweighed into three classifications (overweight, proper weight or lightweight) every minute. With a weighing range between 20 and 1.000 mg, maximum accuracy of ±2 mg at 3s and a maximum speed of 120.000 capsules/hour, the KW9001AP accepts and rejects capsules quickly and efficiently.

Weight
354

CLOSED

Manufacturer
ANRITSU
Model
KW9001AP
Observations
The KW9001AP can measure up to 2.000 capsules/min.; with each capsule individually checkweighed into three classifications (overweight, proper weight or lightweight) every minute. With a weighing range between 20 and 1.000 mg, maximum accuracy of ±2 mg at 3s and a maximum speed of 120.000 capsules/hour, the KW9001AP accepts and rejects capsules quickly and efficiently.

Weight
354

CLOSED

Sold
33  -  capsule check weigher machine
1.500 €

Manufacturer
BWB TECHNOLOGIES UK
Model
XP
No. Series
20090074
Observations
Sample rate 2 - 3.5ml/min Tubing materials Silicone and Tygon Required desk space for Instrument 50cm (H) x 45cm (W) x 45cm (D) For Safety reasons the Flame photometer requires 1m of unobstructed space above to allow dissipation of heat from the chimney. Instrument size XP Flame Photometer 51cm (H) x 39cm (W) x 35cm (D) Shipping 65cm (H) x 49cm (W) x 43cm (D) Weight XP Flame Photometer - 20kg Optimal range Single point calibration Na 0.1 - 60ppm K 0.05 - 100ppm Li 0.05 - 50ppm Ca 1.0 - 100ppm Ba 1.6 - 100ppm Multi Point Calibration Na 0.1 - 1000ppm K 0.05 - 1000ppm Li 0.05 - 1000ppm Ca 1.0 - 1000ppm Ba 5.0 - 3000ppm Reproducibility <1% Coefficient of variability for 20 consecutive samples over ten minutes at concentrations of 100ppm or less. (After instrument stabilisation). Specificity Na/K/Li = <1% to each other when equal in concentration at <100ppm Limit of detection (LOD) and limit of quantification (LOQ) LOD LOQ Na - 0.03ppm Na - 0.1ppm K - 0.02ppm K - 0.05ppm Li - 0.02ppm Li - 0.05ppm Ca - 0.3ppm Ca - 1ppm Ba - 1.6ppm Ba - 5.0ppm Time to stability Less than 15 seconds after sample is introduced into the flame. Ions measured Simultaneous measurement of Na, K, Li, Ca, Ba Interfaces USB 0-2.5 volt output (based on sample concentration linked to element of users choice) Optional 4-20mA output in place of the above Optional integrated printer .csv and .pdf generated reports and files via FP-PC software Recommended minimum warm up time based on ambient temperature 21ºC - 25 minutes Power requirements 100V - 250V AC at 50 or 60Hz automatically selecting Fuel requirement Propane, Butane or Natural Gas* regulated to 19Bar. Flow rate of 0.4l/min Readout LCD, four line, alpha numeric, back lit.

Weight
15

CLOSED

Manufacturer
BWB TECHNOLOGIES UK
Model
XP
No. Series
20090074
Observations
Sample rate 2 - 3.5ml/min Tubing materials Silicone and Tygon Required desk space for Instrument 50cm (H) x 45cm (W) x 45cm (D) For Safety reasons the Flame photometer requires 1m of unobstructed space above to allow dissipation of heat from the chimney. Instrument size XP Flame Photometer 51cm (H) x 39cm (W) x 35cm (D) Shipping 65cm (H) x 49cm (W) x 43cm (D) Weight XP Flame Photometer - 20kg Optimal range Single point calibration Na 0.1 - 60ppm K 0.05 - 100ppm Li 0.05 - 50ppm Ca 1.0 - 100ppm Ba 1.6 - 100ppm Multi Point Calibration Na 0.1 - 1000ppm K 0.05 - 1000ppm Li 0.05 - 1000ppm Ca 1.0 - 1000ppm Ba 5.0 - 3000ppm Reproducibility <1% Coefficient of variability for 20 consecutive samples over ten minutes at concentrations of 100ppm or less. (After instrument stabilisation). Specificity Na/K/Li = <1% to each other when equal in concentration at <100ppm Limit of detection (LOD) and limit of quantification (LOQ) LOD LOQ Na - 0.03ppm Na - 0.1ppm K - 0.02ppm K - 0.05ppm Li - 0.02ppm Li - 0.05ppm Ca - 0.3ppm Ca - 1ppm Ba - 1.6ppm Ba - 5.0ppm Time to stability Less than 15 seconds after sample is introduced into the flame. Ions measured Simultaneous measurement of Na, K, Li, Ca, Ba Interfaces USB 0-2.5 volt output (based on sample concentration linked to element of users choice) Optional 4-20mA output in place of the above Optional integrated printer .csv and .pdf generated reports and files via FP-PC software Recommended minimum warm up time based on ambient temperature 21ºC - 25 minutes Power requirements 100V - 250V AC at 50 or 60Hz automatically selecting Fuel requirement Propane, Butane or Natural Gas* regulated to 19Bar. Flow rate of 0.4l/min Readout LCD, four line, alpha numeric, back lit.

Weight
15

CLOSED

Sold
34  -  Flame Photometer
1.200 €

Manufacturer
CARL KURT WALTHER
Model
LB100
Year
1995
Observations
Tank Capacity : 100Lts

Weight
191

CLOSED

Manufacturer
CARL KURT WALTHER
Model
LB100
Year
1995
Observations
Tank Capacity : 100Lts

Weight
191

CLOSED

Sold
35  -  Mixing inox. tank laboratory
1.000 €

Manufacturer
MACHINES COLLETTE
Model
MP-20
Observations
Mixer capaciry: 20Lts

Weight
192

CLOSED

Manufacturer
MACHINES COLLETTE
Model
MP-20
Observations
Mixer capaciry: 20Lts

Weight
192

CLOSED

Sold
36  -  Stainless Steel Mixer Granulator
1.000 €

Manufacturer
SOCIETE FRANÇAISE D'ETIQUETAGE
Year
1994
No. Series
1452

Weight
216

CLOSED

Manufacturer
SOCIETE FRANÇAISE D'ETIQUETAGE
Year
1994
No. Series
1452

Weight
216

CLOSED

Sold
38  -  Cap labeller machine
1.000 €

Manufacturer
GARDNER DENVER
Model
VTR100
Year
2010
Observations
Dry running rotary vane pump. Volume flow 100 to 120 m³/hr. Ultimate vacuum 150 mbar. 3-3,6Kw. 1.450-1.740 rev/min.

Weight
269

CLOSED

Manufacturer
GARDNER DENVER
Model
VTR100
Year
2010
Observations
Dry running rotary vane pump. Volume flow 100 to 120 m³/hr. Ultimate vacuum 150 mbar. 3-3,6Kw. 1.450-1.740 rev/min.

Weight
269

CLOSED

Sold
39  -  Vacuum pump
1.000 €

Manufacturer
BECKER
Model
U 4.165 F/K
Year
2007
Observations
Volume flow 160 to 192 m³/hr. Ultimate vacuum 0.5 mbar. 4-4.8Kw. 1.420-1.700 rev/min.

Weight
271

CLOSED

Manufacturer
BECKER
Model
U 4.165 F/K
Year
2007
Observations
Volume flow 160 to 192 m³/hr. Ultimate vacuum 0.5 mbar. 4-4.8Kw. 1.420-1.700 rev/min.

Weight
271

CLOSED

Sold
40  -  Vacuum pump
1.000 €

Manufacturer
SEPHA
Observations
Operating Speed: Up to 50 packs per minute Construction: Stainless Steel (Grade 316 & 304) Tooling Changeover: 5 minutes Utilities: Electrical: 110/230V Single Phase AC 50/60 Hz / Air: Min. 450L/min at 0.6Mpa [ISO8573-1:2010 CLASS 2] Machine Dimensions: 965mm (L) 665mm (W) 1540mm (H) Machine Weight: 230kg. Blister Type Push-through, Child resistant, Peelable & Multi-product Pack Dimensions: Width: Min. 82mm Max. 105mm / Length: Min. 33mm Max. 140mm

Weight
307

CLOSED

Manufacturer
SEPHA
Observations
Operating Speed: Up to 50 packs per minute Construction: Stainless Steel (Grade 316 & 304) Tooling Changeover: 5 minutes Utilities: Electrical: 110/230V Single Phase AC 50/60 Hz / Air: Min. 450L/min at 0.6Mpa [ISO8573-1:2010 CLASS 2] Machine Dimensions: 965mm (L) 665mm (W) 1540mm (H) Machine Weight: 230kg. Blister Type Push-through, Child resistant, Peelable & Multi-product Pack Dimensions: Width: Min. 82mm Max. 105mm / Length: Min. 33mm Max. 140mm

Weight
307

CLOSED

Sold
41  -  Deblister Machine standard press out
1.000 €

Manufacturer
TECHNILAB
Model
VTD150MD
Year
2010
Observations
The equipment can dedust up to 500,000 tablets per hour. Equipped with a metal particles detector.

Weight
316

CLOSED

Manufacturer
TECHNILAB
Model
VTD150MD
Year
2010
Observations
The equipment can dedust up to 500,000 tablets per hour. Equipped with a metal particles detector.

Weight
316

CLOSED

Sold
42  -  Tablets Deduster with metal detector
1.000 €

Manufacturer
ROSAND
Model
RH2000
Observations
Maximum force: 12kN (standard) Frame stiffness:100kN. Maximum speed:600mm/min (standard). 1200mm/min (high speed option) Dynamic range in speed:>120,000:1. (240,000:1 with high speed option)Speed uncertainty: <0.1%Temperature range: Ambient to 400°C (standard). Ambient to 500°C (high temperature option). 5°C to 200°C (low temperature cooling coil option)Temperature control range:

Weight
333

CLOSED

Manufacturer
ROSAND
Model
RH2000
Observations
Maximum force: 12kN (standard) Frame stiffness:100kN. Maximum speed:600mm/min (standard). 1200mm/min (high speed option) Dynamic range in speed:>120,000:1. (240,000:1 with high speed option)Speed uncertainty: <0.1%Temperature range: Ambient to 400°C (standard). Ambient to 500°C (high temperature option). 5°C to 200°C (low temperature cooling coil option)Temperature control range:

Weight
333

CLOSED

Sold
43  -  Capillary rheometer
1.000 €

Manufacturer
ANRITSU
Model
K525D CHECKWEIGHER
Observations
Capsule checkweigher. 10 lane, set up for 0 capsules, 110 volt with panel.

Weight
337

CLOSED

Manufacturer
ANRITSU
Model
K525D CHECKWEIGHER
Observations
Capsule checkweigher. 10 lane, set up for 0 capsules, 110 volt with panel.

Weight
337

CLOSED

Sold
44  -  Capsule checkweigher
1.000 €

Manufacturer
ANRITSU
Model
K525D CHECKWEIGHER
Observations
Capsule checkweigher. 10 lane, set up for 0 capsules, 110 volt with panel.

Weight
338

CLOSED

Manufacturer
ANRITSU
Model
K525D CHECKWEIGHER
Observations
Capsule checkweigher. 10 lane, set up for 0 capsules, 110 volt with panel.

Weight
338

CLOSED

Sold
45  -  Capsule checkweigher
1.000 €

Manufacturer
CREMER
Model
CTU1220
Year
2014
No. Series
24597001
Observations
Número de canales de conteo 12; Max. velocidad de conteo 5.500 productos / min. Max. salida 55; Altura de la botella 40-200 mm; Diámetro de la botella 20-110 mm

Weight
356

CLOSED

Manufacturer
CREMER
Model
CTU1220
Year
2014
No. Series
24597001
Observations
Número de canales de conteo 12; Max. velocidad de conteo 5.500 productos / min. Max. salida 55; Altura de la botella 40-200 mm; Diámetro de la botella 20-110 mm

Weight
356

CLOSED

Sold
46  -  linear tablet and capsule counter - 12 channels
1.000 €

Manufacturer
THERMO SCIENTIFIC
Model
MSC 1.2
No. Series
40990208
Observations
Specifications: Exterior dimensions: Depth: 80cm. Height: 152cm. Width: 130cm Certifications/Compliance: EN 12469, by TüV Nord, LNE (0.9 and 1.2m). EN 12469, by TüV Nord (1.5 and 1.8m) Energy Consumption (Reduced Flow Mode): <40w Height (Metric): 152 cm (Exterior) Ports: TUV-Approved Type: Biological Safety Cabinet Width (Metric) Interior: 1.2m Exhaust Air Filter: HEPA H 14 EN 1822, 99.995% at 0.3µm particle Voltage: 230V Energy Consumption (Operating Set Point): 200w Noise Level: <59dBA Receptacles: One double, right side

Weight
289

CLOSED

Manufacturer
THERMO SCIENTIFIC
Model
MSC 1.2
No. Series
40990208
Observations
Specifications: Exterior dimensions: Depth: 80cm. Height: 152cm. Width: 130cm Certifications/Compliance: EN 12469, by TüV Nord, LNE (0.9 and 1.2m). EN 12469, by TüV Nord (1.5 and 1.8m) Energy Consumption (Reduced Flow Mode): <40w Height (Metric): 152 cm (Exterior) Ports: TUV-Approved Type: Biological Safety Cabinet Width (Metric) Interior: 1.2m Exhaust Air Filter: HEPA H 14 EN 1822, 99.995% at 0.3µm particle Voltage: 230V Energy Consumption (Operating Set Point): 200w Noise Level: <59dBA Receptacles: One double, right side

Weight
289

CLOSED

Sold
47  -  biological products safety booth
900 €
Subscribe to our Newsletter

Cookies Policy

We use our own and third-party cookies to obtain statistical data on the navigation of our users and improve our services.

Please note that if you accept third-party cookies, you will need to delete them from your browser settings or through the system provided by the third party itself.

Cerrar

Forgot Password?